Loading files
This file is pinned to the selected release. Download the original to open it in your design tool.
dc34da16aThis file is pinned to the selected release. Download the original to open it in your design tool.
/**
* @file test_pump.c
*
* @brief Unit tests for the pump runtime state machine.
*
* @details
* The pump runtime logic is based on discrete "duration levels".
* This approach avoids using multiplication, since the PIC10F202
* does not provide a hardware multiplication instruction, and
* software emulation would significantly increase memory and
* program size.
*
* The user configures the watering duration by selecting a level.
* Each level represents a fixed time step of 5 seconds.
*
* Level interpretation:
* - Level 1 -> 5 seconds
* - Level 2 -> 10 seconds
* - ...
* - Level 9 -> 45 seconds
*
* Each level corresponds to WATERING_PUMP_STEP_DURATION_SECONDS seconds
* of pump activity.
*
* Runtime model:
*
* 1. remaining_cycle_levels indicates how many duration levels remain
* in the current watering cycle.
* 2. level_remaining_seconds indicates the remaining seconds within
* the current level.
* 3. On each invocation (called once per second):
* - If remaining_cycle_levels == 0 -> pump is OFF.
* - If remaining_cycle_levels > 0 -> pump is ON.
* - level_remaining_seconds is decremented.
* - When level_remaining_seconds reaches 0:
* remaining_cycle_levels is decremented.
* If remaining_cycle_levels > 0, level_remaining_seconds
* resets to WATERING_PUMP_STEP_DURATION_SECONDS.
*
* The tests below verify all state transitions and boundary conditions
* of this state machine.
*/
#include "unity.h"
#include "xc.h"
#include "watering.h"
extern void watering_handle_pump(void);
extern PlantWateringData data;
#define MOSFET_PIN GPIObits.GP2
/* Test-local definitions matching production polarity */
#define GPIO_LEVEL_LOW (0U)
#define GPIO_LEVEL_HIGH (1U)
#define PUMP_ON GPIO_LEVEL_HIGH
#define PUMP_OFF GPIO_LEVEL_LOW
/** Minimum selectable pump duration level (in steps). */
#define WATERING_PUMP_DURATION_LEVEL_MIN (1U)
/** Duration of one pump level in seconds. */
#define WATERING_PUMP_STEP_DURATION_SECONDS (5U)
void setUp(void)
{
MOSFET_PIN = GPIO_LEVEL_LOW;
data.pump.configured_duration_level = WATERING_PUMP_DURATION_LEVEL_MIN;
data.pump.remaining_cycle_levels = 0U;
data.pump.level_remaining_seconds = 0U;
}
void tearDown(void) {}
/* ================================================================
* GROUP 1: IDLE STATE BEHAVIOR
* ================================================================ */
/**
* @brief Verify pump remains OFF when no remaining levels exist.
*/
void test_idle_pump_remains_off(void)
{
data.pump.remaining_cycle_levels = 0U;
data.pump.level_remaining_seconds = 0U;
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8(PUMP_OFF, MOSFET_PIN);
}
/**
* @brief Verify pump remains OFF even if level_remaining_seconds
* contains a stale nonzero value.
*
* Guards against a logic error where level_remaining_seconds is
* evaluated independently of remaining_cycle_levels.
*/
void test_idle_pump_off_despite_stale_seconds(void)
{
data.pump.remaining_cycle_levels = 0U;
data.pump.level_remaining_seconds = WATERING_PUMP_STEP_DURATION_SECONDS;
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8(PUMP_OFF, MOSFET_PIN);
}
/**
* @brief Verify level_remaining_seconds is not modified when idle.
*
* watering_handle_pump must not decrement or reset level_remaining_seconds
* when remaining_cycle_levels is zero.
*/
void test_idle_does_not_modify_level_remaining_seconds(void)
{
data.pump.remaining_cycle_levels = 0U;
data.pump.level_remaining_seconds = 3U;
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8(3U, data.pump.level_remaining_seconds);
}
/**
* @brief Verify remaining_cycle_levels is not modified when idle.
*/
void test_idle_does_not_modify_remaining_cycle_levels(void)
{
data.pump.remaining_cycle_levels = 0U;
data.pump.level_remaining_seconds = 0U;
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8(0U, data.pump.remaining_cycle_levels);
}
/**
* @brief Verify pump remains OFF across multiple consecutive idle calls.
*/
void test_consecutive_idle_calls_remain_off(void)
{
data.pump.remaining_cycle_levels = 0U;
data.pump.level_remaining_seconds = 0U;
for (uint8_t i = 0; i < 10U; i++)
{
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8(PUMP_OFF, MOSFET_PIN);
}
}
/* ================================================================
* GROUP 2: ACTIVE STATE — BASIC BEHAVIOR
* ================================================================ */
/**
* @brief Verify pump turns ON when remaining_cycle_levels > 0.
*/
void test_active_pump_turns_on(void)
{
data.pump.remaining_cycle_levels = 1U;
data.pump.level_remaining_seconds = WATERING_PUMP_STEP_DURATION_SECONDS;
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8(PUMP_ON, MOSFET_PIN);
}
/**
* @brief Verify level_remaining_seconds decrements by exactly 1
* per call and remaining_cycle_levels is unchanged.
*/
void test_active_seconds_decrement_without_level_change(void)
{
data.pump.remaining_cycle_levels = 2U;
data.pump.level_remaining_seconds = WATERING_PUMP_STEP_DURATION_SECONDS;
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8(WATERING_PUMP_STEP_DURATION_SECONDS - 1U,
data.pump.level_remaining_seconds);
TEST_ASSERT_EQUAL_UINT8(2U, data.pump.remaining_cycle_levels);
TEST_ASSERT_EQUAL_UINT8(PUMP_ON, MOSFET_PIN);
}
/**
* @brief Verify configured_duration_level is never modified by
* watering_handle_pump across an entire watering cycle.
*
* configured_duration_level is a user setting and must remain
* constant throughout pump operation.
*/
void test_active_configured_duration_unchanged(void)
{
data.pump.configured_duration_level = 7U;
data.pump.remaining_cycle_levels = 3U;
data.pump.level_remaining_seconds = WATERING_PUMP_STEP_DURATION_SECONDS;
/* Run through the entire cycle and beyond into idle */
const uint8_t total_calls =
(3U * WATERING_PUMP_STEP_DURATION_SECONDS) + 5U;
for (uint8_t i = 0; i < total_calls; i++)
{
watering_handle_pump();
}
TEST_ASSERT_EQUAL_UINT8(7U, data.pump.configured_duration_level);
}
/* ================================================================
* GROUP 3: LEVEL TRANSITIONS
* ================================================================ */
/**
* @brief Verify level transition: when seconds expire with multiple
* remaining levels, the level decrements and seconds reset.
*/
void test_level_transition_decrements_and_resets_seconds(void)
{
data.pump.remaining_cycle_levels = 2U;
data.pump.level_remaining_seconds = 1U;
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8(1U, data.pump.remaining_cycle_levels);
TEST_ASSERT_EQUAL_UINT8(WATERING_PUMP_STEP_DURATION_SECONDS,
data.pump.level_remaining_seconds);
TEST_ASSERT_EQUAL_UINT8(PUMP_ON, MOSFET_PIN);
}
/**
* @brief Verify seconds countdown through an entire single level.
*
* Traces every second within one level to detect off-by-one errors
* in the decrement sequence.
*/
void test_seconds_countdown_through_entire_level(void)
{
data.pump.remaining_cycle_levels = 1U;
data.pump.level_remaining_seconds = WATERING_PUMP_STEP_DURATION_SECONDS;
for (uint8_t expected = WATERING_PUMP_STEP_DURATION_SECONDS;
expected > 1U; expected--)
{
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8(expected - 1U,
data.pump.level_remaining_seconds);
TEST_ASSERT_EQUAL_UINT8(1U,
data.pump.remaining_cycle_levels);
}
/* Final second of this level */
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8(0U, data.pump.remaining_cycle_levels);
TEST_ASSERT_EQUAL_UINT8(0U, data.pump.level_remaining_seconds);
}
/**
* @brief Verify final level completion: remaining reaches 0,
* seconds remain 0, and pump is ON during this call.
*
* Critical safety check: the pump must be ON for exactly the
* configured number of seconds, including this final second.
*/
void test_final_level_completion_pump_on_and_state_zeroed(void)
{
data.pump.remaining_cycle_levels = 1U;
data.pump.level_remaining_seconds = 1U;
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8(0U, data.pump.remaining_cycle_levels);
TEST_ASSERT_EQUAL_UINT8(0U, data.pump.level_remaining_seconds);
/* Pump must be ON during this final active call */
TEST_ASSERT_EQUAL_UINT8(PUMP_ON, MOSFET_PIN);
}
/**
* @brief Verify that level_remaining_seconds is NOT reset to
* WATERING_PUMP_STEP_DURATION_SECONDS when remaining_cycle_levels
* reaches zero.
*
* Documents the correct terminal state. If seconds were
* erroneously reset, subsequent re-activation logic could
* inherit a stale value.
*/
void test_final_level_seconds_not_reset(void)
{
data.pump.remaining_cycle_levels = 1U;
data.pump.level_remaining_seconds = 1U;
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8(0U, data.pump.level_remaining_seconds);
TEST_ASSERT_NOT_EQUAL(WATERING_PUMP_STEP_DURATION_SECONDS,
data.pump.level_remaining_seconds);
}
/* ================================================================
* GROUP 4: ACTIVE-TO-IDLE TRANSITION
* ================================================================ */
/**
* @brief Verify pump turns OFF on the first call after cycle
* completion.
*
* This is the critical safety transition: after the last active
* second, the next call must turn the MOSFET OFF.
*/
void test_pump_off_on_call_after_completion(void)
{
data.pump.remaining_cycle_levels = 1U;
data.pump.level_remaining_seconds = 1U;
/* Final active call */
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8(PUMP_ON, MOSFET_PIN);
/* First idle call — pump must be OFF */
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8(PUMP_OFF, MOSFET_PIN);
}
/**
* @brief Verify pump can be re-activated after returning to idle.
*/
void test_reactivation_after_completion(void)
{
/* Complete a cycle */
data.pump.remaining_cycle_levels = 1U;
data.pump.level_remaining_seconds = 1U;
watering_handle_pump();
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8(PUMP_OFF, MOSFET_PIN);
/* Re-activate */
data.pump.remaining_cycle_levels = 2U;
data.pump.level_remaining_seconds = WATERING_PUMP_STEP_DURATION_SECONDS;
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8(PUMP_ON, MOSFET_PIN);
TEST_ASSERT_EQUAL_UINT8(2U, data.pump.remaining_cycle_levels);
TEST_ASSERT_EQUAL_UINT8(WATERING_PUMP_STEP_DURATION_SECONDS - 1U,
data.pump.level_remaining_seconds);
}
/* ================================================================
* GROUP 5: FULL CYCLE END-TO-END VERIFICATION
* ================================================================ */
/**
* @brief Verify exact pump ON duration for a single-level cycle
* (level 1 = 5 seconds).
*/
void test_full_cycle_single_level(void)
{
data.pump.remaining_cycle_levels = 1U;
data.pump.level_remaining_seconds = WATERING_PUMP_STEP_DURATION_SECONDS;
const uint8_t expected_on = WATERING_PUMP_STEP_DURATION_SECONDS;
const uint8_t total_calls = expected_on + 1U;
uint8_t on_count = 0U;
for (uint8_t i = 0; i < total_calls; i++)
{
watering_handle_pump();
if (MOSFET_PIN == PUMP_ON)
{
on_count++;
}
}
TEST_ASSERT_EQUAL_UINT8(expected_on, on_count);
TEST_ASSERT_EQUAL_UINT8(0U, data.pump.remaining_cycle_levels);
TEST_ASSERT_EQUAL_UINT8(PUMP_OFF, MOSFET_PIN);
}
/**
* @brief Verify exact pump ON duration for a two-level cycle
* (level 2 = 10 seconds).
*/
void test_full_cycle_two_levels(void)
{
data.pump.remaining_cycle_levels = 2U;
data.pump.level_remaining_seconds = WATERING_PUMP_STEP_DURATION_SECONDS;
const uint8_t expected_on = 2U * WATERING_PUMP_STEP_DURATION_SECONDS;
const uint8_t total_calls = expected_on + 1U;
uint8_t on_count = 0U;
for (uint8_t i = 0; i < total_calls; i++)
{
watering_handle_pump();
if (MOSFET_PIN == PUMP_ON)
{
on_count++;
}
}
TEST_ASSERT_EQUAL_UINT8(expected_on, on_count);
TEST_ASSERT_EQUAL_UINT8(0U, data.pump.remaining_cycle_levels);
TEST_ASSERT_EQUAL_UINT8(PUMP_OFF, MOSFET_PIN);
}
/**
* @brief Verify exact pump ON duration for maximum level cycle
* (level 9 = 45 seconds).
*
* Boundary test for the highest user-selectable duration.
*/
void test_full_cycle_max_level(void)
{
const uint8_t max_level = 9U;
data.pump.remaining_cycle_levels = max_level;
data.pump.level_remaining_seconds = WATERING_PUMP_STEP_DURATION_SECONDS;
const uint8_t expected_on =
max_level * WATERING_PUMP_STEP_DURATION_SECONDS;
const uint8_t total_calls = expected_on + 1U;
uint8_t on_count = 0U;
for (uint8_t i = 0; i < total_calls; i++)
{
watering_handle_pump();
if (MOSFET_PIN == PUMP_ON)
{
on_count++;
}
}
TEST_ASSERT_EQUAL_UINT8(expected_on, on_count);
TEST_ASSERT_EQUAL_UINT8(0U, data.pump.remaining_cycle_levels);
TEST_ASSERT_EQUAL_UINT8(PUMP_OFF, MOSFET_PIN);
}
/**
* @brief Verify MOSFET is ON for every single call during an
* active cycle and OFF immediately after.
*
* Traces every call individually to detect any premature OFF
* glitch during level transitions.
*/
void test_mosfet_on_every_active_call(void)
{
data.pump.remaining_cycle_levels = 3U;
data.pump.level_remaining_seconds = WATERING_PUMP_STEP_DURATION_SECONDS;
const uint8_t expected_on = 3U * WATERING_PUMP_STEP_DURATION_SECONDS;
for (uint8_t i = 0; i < expected_on; i++)
{
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8_MESSAGE(
PUMP_ON, MOSFET_PIN,
"MOSFET unexpectedly OFF during active cycle");
}
/* Next call must turn OFF */
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8(PUMP_OFF, MOSFET_PIN);
}
/* ================================================================
* GROUP 6: MINIMUM ACTIVE STATE
* ================================================================ */
/**
* @brief Verify correct behavior with the minimum possible active
* state: one level, one remaining second.
*
* This is the smallest unit of pump activity. The pump must be ON
* for exactly one call and OFF on the next.
*/
void test_minimum_active_state(void)
{
data.pump.remaining_cycle_levels = 1U;
data.pump.level_remaining_seconds = 1U;
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8(PUMP_ON, MOSFET_PIN);
TEST_ASSERT_EQUAL_UINT8(0U, data.pump.remaining_cycle_levels);
watering_handle_pump();
TEST_ASSERT_EQUAL_UINT8(PUMP_OFF, MOSFET_PIN);
}
/* Unity test runner */
int main(void)
{
UNITY_BEGIN();
/* Group 1: Idle state */
RUN_TEST(test_idle_pump_remains_off);
RUN_TEST(test_idle_pump_off_despite_stale_seconds);
RUN_TEST(test_idle_does_not_modify_level_remaining_seconds);
RUN_TEST(test_idle_does_not_modify_remaining_cycle_levels);
RUN_TEST(test_consecutive_idle_calls_remain_off);
/* Group 2: Active state basics */
RUN_TEST(test_active_pump_turns_on);
RUN_TEST(test_active_seconds_decrement_without_level_change);
RUN_TEST(test_active_configured_duration_unchanged);
/* Group 3: Level transitions */
RUN_TEST(test_level_transition_decrements_and_resets_seconds);
RUN_TEST(test_seconds_countdown_through_entire_level);
RUN_TEST(test_final_level_completion_pump_on_and_state_zeroed);
RUN_TEST(test_final_level_seconds_not_reset);
/* Group 4: Active-to-idle transition */
RUN_TEST(test_pump_off_on_call_after_completion);
RUN_TEST(test_reactivation_after_completion);
/* Group 5: Full cycle end-to-end */
RUN_TEST(test_full_cycle_single_level);
RUN_TEST(test_full_cycle_two_levels);
RUN_TEST(test_full_cycle_max_level);
RUN_TEST(test_mosfet_on_every_active_call);
/* Group 6: Minimum active state */
RUN_TEST(test_minimum_active_state);
return UNITY_END();
}