Loading files
This file is pinned to the selected release. Download the original to open it in your design tool.
/**
* @file test_watering_handle_sensor_check.c
*
* @brief Unit tests for the soil moisture sensor check logic.
*
* @details
* watering_handle_sensor_check() is called once per hour by the main loop
* timebase. It reads the soil moisture sensor and, if the soil is
* dry, schedules a pump activation cycle.
*
* Behavior:
*
* 1. Sensor read: GPIO_SOIL_SENSOR_INPUT is sampled.
* LOW = soil is dry (watering required).
* HIGH = soil is wet (no action).
*
* 2. Activation: When soil is dry:
* - remaining_cycle_levels is loaded from configured_duration_level.
* - level_remaining_seconds is reset to WATERING_PUMP_STEP_DURATION_SECONDS.
*
* 3. No action: When soil is wet, no state is modified.
*
* Architectural constraints:
* - Pump runtime is shorter than the soil-check interval; therefore,
* the pump will always be idle when watering_handle_sensor_check is called
* under normal operation. However, the function itself does not
* enforce this.
*
* The tests below verify sensor response, state loading, boundary
* conditions, and state isolation.
*/
#include "unity.h"
#include "xc.h"
#include "watering.h"
extern void watering_handle_sensor_check(void);
extern PlantWateringData data;
#define SOIL_SENSOR_PIN GPIObits.GP1
#define GPIO_LEVEL_LOW (0U)
#define GPIO_LEVEL_HIGH (1U)
#define SOIL_DRY GPIO_LEVEL_LOW
#define SOIL_WET GPIO_LEVEL_HIGH
/**
* @note WATERING_PUMP_DURATION_LEVEL_MAX is defined in watering.c (translation
* unit scope). Duplicated here for boundary verification.
* Must be kept in sync with the production definition.
*/
#define WATERING_PUMP_DURATION_LEVEL_MAX (9U)
/** Minimum selectable pump duration level (in steps). */
#define WATERING_PUMP_DURATION_LEVEL_MIN (1U)
/** Duration of one pump level in seconds. */
#define WATERING_PUMP_STEP_DURATION_SECONDS (5U)
void setUp(void)
{
SOIL_SENSOR_PIN = SOIL_WET;
data.pump.configured_duration_level = WATERING_PUMP_DURATION_LEVEL_MIN;
data.pump.remaining_cycle_levels = 0U;
data.pump.level_remaining_seconds = 0U;
data.send_pulse_to_display = false;
data.sending_pulse_to_display = false;
data.button_was_pressed = false;
}
void tearDown(void) {}
/* ================================================================
* GROUP 1: SOIL WET — NO ACTION
* ================================================================ */
/**
* @brief Verify no activation when soil is wet.
*/
void test_wet_no_activation(void)
{
SOIL_SENSOR_PIN = SOIL_WET;
data.pump.configured_duration_level = 5U;
data.pump.remaining_cycle_levels = 0U;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8(0U, data.pump.remaining_cycle_levels);
}
/**
* @brief Verify level_remaining_seconds unchanged when wet.
*/
void test_wet_seconds_unchanged(void)
{
SOIL_SENSOR_PIN = SOIL_WET;
data.pump.level_remaining_seconds = 0U;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8(0U, data.pump.level_remaining_seconds);
}
/**
* @brief Verify level_remaining_seconds with nonzero stale value
* is not modified when wet.
*
* Guards against the function resetting seconds to
* WATERING_PUMP_STEP_DURATION_SECONDS regardless of sensor state.
*/
void test_wet_stale_seconds_not_modified(void)
{
SOIL_SENSOR_PIN = SOIL_WET;
data.pump.level_remaining_seconds = 3U;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8(3U, data.pump.level_remaining_seconds);
}
/**
* @brief Verify configured_duration_level is never modified
* when wet.
*/
void test_wet_configured_duration_unchanged(void)
{
SOIL_SENSOR_PIN = SOIL_WET;
data.pump.configured_duration_level = 7U;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8(7U, data.pump.configured_duration_level);
}
/**
* @brief Verify remaining_cycle_levels with a stale nonzero value
* is not modified when wet.
*
* Although architecturally the pump is idle when this function is
* called, the function itself must not clear remaining_cycle_levels.
*/
void test_wet_stale_remaining_not_modified(void)
{
SOIL_SENSOR_PIN = SOIL_WET;
data.pump.remaining_cycle_levels = 4U;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8(4U, data.pump.remaining_cycle_levels);
}
/**
* @brief Verify display flags are not modified when wet.
*/
void test_wet_display_flags_unchanged(void)
{
SOIL_SENSOR_PIN = SOIL_WET;
data.send_pulse_to_display = false;
data.sending_pulse_to_display = true;
watering_handle_sensor_check();
TEST_ASSERT_FALSE(data.send_pulse_to_display);
TEST_ASSERT_TRUE(data.sending_pulse_to_display);
}
/**
* @brief Verify button state is not modified when wet.
*/
void test_wet_button_state_unchanged(void)
{
SOIL_SENSOR_PIN = SOIL_WET;
data.button_was_pressed = true;
watering_handle_sensor_check();
TEST_ASSERT_TRUE(data.button_was_pressed);
}
/**
* @brief Verify consecutive wet checks produce no state change.
*/
void test_wet_consecutive_calls_no_change(void)
{
SOIL_SENSOR_PIN = SOIL_WET;
data.pump.configured_duration_level = 3U;
data.pump.remaining_cycle_levels = 0U;
data.pump.level_remaining_seconds = 0U;
for (uint8_t i = 0; i < 10U; i++)
{
watering_handle_sensor_check();
}
TEST_ASSERT_EQUAL_UINT8(0U, data.pump.remaining_cycle_levels);
TEST_ASSERT_EQUAL_UINT8(0U, data.pump.level_remaining_seconds);
TEST_ASSERT_EQUAL_UINT8(3U, data.pump.configured_duration_level);
}
/* ================================================================
* GROUP 2: SOIL DRY — ACTIVATION
* ================================================================ */
/**
* @brief Verify remaining_cycle_levels is loaded from
* configured_duration_level when dry.
*/
void test_dry_loads_remaining_from_configured(void)
{
SOIL_SENSOR_PIN = SOIL_DRY;
data.pump.configured_duration_level = 5U;
data.pump.remaining_cycle_levels = 0U;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8(5U, data.pump.remaining_cycle_levels);
}
/**
* @brief Verify level_remaining_seconds is reset to
* WATERING_PUMP_STEP_DURATION_SECONDS when dry.
*/
void test_dry_resets_seconds(void)
{
SOIL_SENSOR_PIN = SOIL_DRY;
data.pump.configured_duration_level = 3U;
data.pump.level_remaining_seconds = 0U;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8(WATERING_PUMP_STEP_DURATION_SECONDS,
data.pump.level_remaining_seconds);
}
/**
* @brief Verify level_remaining_seconds is reset even if it
* already holds a stale nonzero value.
*/
void test_dry_resets_seconds_from_stale_value(void)
{
SOIL_SENSOR_PIN = SOIL_DRY;
data.pump.configured_duration_level = 2U;
data.pump.level_remaining_seconds = 99U;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8(WATERING_PUMP_STEP_DURATION_SECONDS,
data.pump.level_remaining_seconds);
}
/**
* @brief Verify configured_duration_level is not modified when dry.
*
* The function must only read, not write, the user setting.
*/
void test_dry_configured_duration_unchanged(void)
{
SOIL_SENSOR_PIN = SOIL_DRY;
data.pump.configured_duration_level = 8U;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8(8U, data.pump.configured_duration_level);
}
/* ================================================================
* GROUP 3: BOUNDARY — MINIMUM CONFIGURED LEVEL
* ================================================================ */
/**
* @brief Verify activation with minimum configured level (1).
*
* remaining_cycle_levels must be exactly 1, not 0.
*/
void test_dry_min_level_loads_correctly(void)
{
SOIL_SENSOR_PIN = SOIL_DRY;
data.pump.configured_duration_level = WATERING_PUMP_DURATION_LEVEL_MIN;
data.pump.remaining_cycle_levels = 0U;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8(WATERING_PUMP_DURATION_LEVEL_MIN,
data.pump.remaining_cycle_levels);
TEST_ASSERT_EQUAL_UINT8(WATERING_PUMP_STEP_DURATION_SECONDS,
data.pump.level_remaining_seconds);
}
/**
* @brief Verify remaining_cycle_levels is not zero after min
* level activation.
*
* Explicit zero-exclusion. If remaining is zero, watering_handle_pump
* would never turn the pump on.
*/
void test_dry_min_level_remaining_not_zero(void)
{
SOIL_SENSOR_PIN = SOIL_DRY;
data.pump.configured_duration_level = WATERING_PUMP_DURATION_LEVEL_MIN;
data.pump.remaining_cycle_levels = 0U;
watering_handle_sensor_check();
TEST_ASSERT_NOT_EQUAL(0U, data.pump.remaining_cycle_levels);
}
/* ================================================================
* GROUP 4: BOUNDARY — MAXIMUM CONFIGURED LEVEL
* ================================================================ */
/**
* @brief Verify activation with maximum configured level (9).
*/
void test_dry_max_level_loads_correctly(void)
{
SOIL_SENSOR_PIN = SOIL_DRY;
data.pump.configured_duration_level = WATERING_PUMP_DURATION_LEVEL_MAX;
data.pump.remaining_cycle_levels = 0U;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8(WATERING_PUMP_DURATION_LEVEL_MAX,
data.pump.remaining_cycle_levels);
TEST_ASSERT_EQUAL_UINT8(WATERING_PUMP_STEP_DURATION_SECONDS,
data.pump.level_remaining_seconds);
}
/**
* @brief Verify seconds is exactly WATERING_PUMP_STEP_DURATION_SECONDS
* at max level, not scaled by level.
*
* Guards against an implementation that multiplies seconds by
* the level count.
*/
void test_dry_max_level_seconds_not_scaled(void)
{
SOIL_SENSOR_PIN = SOIL_DRY;
data.pump.configured_duration_level = WATERING_PUMP_DURATION_LEVEL_MAX;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8(WATERING_PUMP_STEP_DURATION_SECONDS,
data.pump.level_remaining_seconds);
}
/* ================================================================
* GROUP 5: EVERY CONFIGURED LEVEL
* ================================================================ */
/**
* @brief Verify correct activation for every level from MIN to MAX.
*
* Exhaustive sweep: detects any level-specific loading error.
*/
void test_dry_all_levels_load_correctly(void)
{
for (uint8_t level = WATERING_PUMP_DURATION_LEVEL_MIN;
level <= WATERING_PUMP_DURATION_LEVEL_MAX; level++)
{
SOIL_SENSOR_PIN = SOIL_DRY;
data.pump.configured_duration_level = level;
data.pump.remaining_cycle_levels = 0U;
data.pump.level_remaining_seconds = 0U;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8_MESSAGE(
level, data.pump.remaining_cycle_levels,
"remaining_cycle_levels mismatch");
TEST_ASSERT_EQUAL_UINT8_MESSAGE(
WATERING_PUMP_STEP_DURATION_SECONDS,
data.pump.level_remaining_seconds,
"level_remaining_seconds mismatch");
}
}
/* ================================================================
* GROUP 6: STATE ISOLATION — DRY PATH
* ================================================================ */
/**
* @brief Verify display flags are not modified when dry.
*
* watering_handle_sensor_check must not trigger display pulses.
*/
void test_dry_display_flags_unchanged(void)
{
SOIL_SENSOR_PIN = SOIL_DRY;
data.pump.configured_duration_level = 3U;
data.send_pulse_to_display = false;
data.sending_pulse_to_display = true;
watering_handle_sensor_check();
TEST_ASSERT_FALSE(data.send_pulse_to_display);
TEST_ASSERT_TRUE(data.sending_pulse_to_display);
}
/**
* @brief Verify button state is not modified when dry.
*/
void test_dry_button_state_unchanged(void)
{
SOIL_SENSOR_PIN = SOIL_DRY;
data.pump.configured_duration_level = 3U;
data.button_was_pressed = true;
watering_handle_sensor_check();
TEST_ASSERT_TRUE(data.button_was_pressed);
}
/* ================================================================
* GROUP 7: SENSOR POLARITY VERIFICATION
* ================================================================ */
/**
* @brief Verify LOW sensor value is interpreted as dry (activate).
*
* Explicit polarity check. Detects inverted sensor logic.
*/
void test_sensor_low_is_dry(void)
{
SOIL_SENSOR_PIN = GPIO_LEVEL_LOW;
data.pump.configured_duration_level = 5U;
data.pump.remaining_cycle_levels = 0U;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8(5U, data.pump.remaining_cycle_levels);
}
/**
* @brief Verify HIGH sensor value is interpreted as wet (no action).
*
* Explicit polarity check. Detects inverted sensor logic.
*/
void test_sensor_high_is_wet(void)
{
SOIL_SENSOR_PIN = GPIO_LEVEL_HIGH;
data.pump.configured_duration_level = 5U;
data.pump.remaining_cycle_levels = 0U;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8(0U, data.pump.remaining_cycle_levels);
}
/* ================================================================
* GROUP 8: CONSECUTIVE DRY CHECKS (IDEMPOTENCY)
* ================================================================ */
/**
* @brief Verify consecutive dry checks reload state identically.
*
* If the sensor remains dry across multiple hourly checks and
* the pump has already finished, the function must reload the
* same values. This verifies no accumulation or drift occurs.
*/
void test_dry_consecutive_reloads_identical(void)
{
SOIL_SENSOR_PIN = SOIL_DRY;
data.pump.configured_duration_level = 4U;
for (uint8_t i = 0; i < 5U; i++)
{
data.pump.remaining_cycle_levels = 0U;
data.pump.level_remaining_seconds = 0U;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8(4U,
data.pump.remaining_cycle_levels);
TEST_ASSERT_EQUAL_UINT8(WATERING_PUMP_STEP_DURATION_SECONDS,
data.pump.level_remaining_seconds);
}
}
/**
* @brief Verify that calling watering_handle_sensor_check while the pump
* is still running overwrites remaining_cycle_levels.
*
* Under normal operation this cannot happen (pump finishes before
* next hourly check). However, the function has no guard against
* it, so this test documents the actual behavior: an unconditional
* overwrite occurs.
*/
void test_dry_overwrites_active_remaining(void)
{
SOIL_SENSOR_PIN = SOIL_DRY;
data.pump.configured_duration_level = 3U;
data.pump.remaining_cycle_levels = 7U;
data.pump.level_remaining_seconds = 2U;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8(3U, data.pump.remaining_cycle_levels);
TEST_ASSERT_EQUAL_UINT8(WATERING_PUMP_STEP_DURATION_SECONDS,
data.pump.level_remaining_seconds);
}
/* ================================================================
* GROUP 9: WET-DRY-WET TRANSITION SEQUENCE
* ================================================================ */
/**
* @brief Verify correct behavior across a wet-dry-wet sequence.
*
* Simulates a sensor transition: no action, activation, no action.
* Verifies that only the dry check activates the pump and that
* a subsequent wet check does not cancel or modify the activation.
*/
void test_wet_dry_wet_sequence(void)
{
data.pump.configured_duration_level = 6U;
data.pump.remaining_cycle_levels = 0U;
data.pump.level_remaining_seconds = 0U;
/* Wet: no action */
SOIL_SENSOR_PIN = SOIL_WET;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8(0U, data.pump.remaining_cycle_levels);
/* Dry: activate */
SOIL_SENSOR_PIN = SOIL_DRY;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8(6U, data.pump.remaining_cycle_levels);
TEST_ASSERT_EQUAL_UINT8(WATERING_PUMP_STEP_DURATION_SECONDS,
data.pump.level_remaining_seconds);
/* Wet: must not cancel activation */
SOIL_SENSOR_PIN = SOIL_WET;
watering_handle_sensor_check();
TEST_ASSERT_EQUAL_UINT8(6U, data.pump.remaining_cycle_levels);
TEST_ASSERT_EQUAL_UINT8(WATERING_PUMP_STEP_DURATION_SECONDS,
data.pump.level_remaining_seconds);
}
/* Unity test runner */
int main(void)
{
UNITY_BEGIN();
/* Group 1: Soil wet — no action */
RUN_TEST(test_wet_no_activation);
RUN_TEST(test_wet_seconds_unchanged);
RUN_TEST(test_wet_stale_seconds_not_modified);
RUN_TEST(test_wet_configured_duration_unchanged);
RUN_TEST(test_wet_stale_remaining_not_modified);
RUN_TEST(test_wet_display_flags_unchanged);
RUN_TEST(test_wet_button_state_unchanged);
RUN_TEST(test_wet_consecutive_calls_no_change);
/* Group 2: Soil dry — activation */
RUN_TEST(test_dry_loads_remaining_from_configured);
RUN_TEST(test_dry_resets_seconds);
RUN_TEST(test_dry_resets_seconds_from_stale_value);
RUN_TEST(test_dry_configured_duration_unchanged);
/* Group 3: Boundary — minimum level */
RUN_TEST(test_dry_min_level_loads_correctly);
RUN_TEST(test_dry_min_level_remaining_not_zero);
/* Group 4: Boundary — maximum level */
RUN_TEST(test_dry_max_level_loads_correctly);
RUN_TEST(test_dry_max_level_seconds_not_scaled);
/* Group 5: Every level */
RUN_TEST(test_dry_all_levels_load_correctly);
/* Group 6: State isolation — dry path */
RUN_TEST(test_dry_display_flags_unchanged);
RUN_TEST(test_dry_button_state_unchanged);
/* Group 7: Sensor polarity */
RUN_TEST(test_sensor_low_is_dry);
RUN_TEST(test_sensor_high_is_wet);
/* Group 8: Consecutive dry checks */
RUN_TEST(test_dry_consecutive_reloads_identical);
RUN_TEST(test_dry_overwrites_active_remaining);
/* Group 9: Transition sequence */
RUN_TEST(test_wet_dry_wet_sequence);
return UNITY_END();
}dc34da16aThis file is pinned to the selected release. Download the original to open it in your design tool.