// Driver for the Sensirion SCD41 CO2 / temperature / humidity sensor.
// Used on the AirCube "Pro" hardware variant.
//
#ifndef AIRCUBE_SCD41_H
#define AIRCUBE_SCD41_H
#include <stdint.h>
#include <stdbool.h>
#include "esp_err.h"
// Bus address, exposed so the model detection can probe for this sensor without
// pulling in the driver.
#define SCD41_I2C_ADDRESS 0x62
// Probe for the sensor, apply the static temperature offset, and start
// low-power periodic measurement mode (~30-second CO2/RH/T updates).
// Safe to call on hardware that does not have the SCD41 fitted (Base model):
// it will simply mark the sensor as not present.
void scd41_init(void);
// Returns true if the SCD41 was detected during scd41_init().
bool scd41_is_present(void);
// Polls data-ready in low-power periodic mode. Call frequently (e.g. once per
// sensor-task loop); when the sensor's ~30-second frame is ready, reads CO2,
// temperature and humidity together and updates the cached getters.
// Returns true when fresh values were read on this call.
bool scd41_poll(void);
// Cached values from the most recent accepted measurement. Only meaningful
// while scd41_has_data() is true.
uint16_t scd41_get_co2(void); // CO2 concentration in ppm
float scd41_get_temperature_c(void); // temperature in degrees Celsius
float scd41_get_humidity(void); // relative humidity in %
// True only while the cached temperature/humidity can be trusted: at least one
// measurement has been accepted, it is recent, and no stuck-channel fault is
// latched. False during the initial ~30 s measurement and again once readings go
// stale, so callers never publish an old value as if it were current.
bool scd41_has_data(void);
// True while the cached CO2 value can be trusted. Tracked separately so a
// T/RH-only fault can withhold those channels without discarding valid CO2.
bool scd41_has_co2(void);
// Snapshot of driver health, for serial diagnostics and fault reporting.
typedef struct {
bool present; // sensor ACKed at init
bool data_valid; // same condition as scd41_has_data()
bool co2_valid; // same condition as scd41_has_co2()
bool stuck_latched; // identical T/RH words for too long
uint32_t consecutive_failures; // failed reads since the last good one
uint32_t identical_streak; // consecutive bit-identical T/RH pairs
uint32_t stuck_events; // times a stuck fault has latched
uint32_t recovery_attempts; // reinit attempts since boot
uint32_t rejected_samples; // reads dropped as implausible
int64_t last_good_age_ms; // age of last accepted T/RH, -1 if never
int64_t last_co2_age_ms; // age of last accepted CO2, -1 if never
} scd41_health_t;
void scd41_get_health(scd41_health_t *out);
// The most recent read_measurement response, kept for field triage: this is
// what identifies a sensor that is returning constant but CRC-valid data.
typedef struct {
bool valid; // a frame has been captured since boot
uint8_t bytes[9]; // raw response, 3 words of [MSB, LSB, CRC]
uint16_t words[3]; // decoded CO2, temperature, humidity words
uint8_t crc_mask; // bit i set = word i passed its CRC
int64_t age_ms; // how long ago the frame was read
} scd41_raw_frame_t;
bool scd41_get_raw_frame(scd41_raw_frame_t *out);
// Run the sensor's built-in self test (~10 s, blocking). On success *result is
// the raw status word, which is 0 when no malfunction is detected.
esp_err_t scd41_self_test(uint16_t *result);
// stop_periodic_measurement + reinit + re-apply the temperature offset, then
// restart low-power periodic mode. Clears failure counters but retains a stuck
// fault until genuinely moving readings arrive. Never performs a factory reset.
esp_err_t scd41_reinit(void);
#endif // AIRCUBE_SCD41_H