* spi.c
*
* Created on: Oct 25, 2016
* Author: Bumsik Kim
*/
#include "common_source.h"
#include "adc.h"
/* Changing base name. Used with msg(). See @base.h */
#ifdef KB_MSG_BASE
#undef KB_MSG_BASE
#define KB_MSG_BASE "ADC"
#endif
/* Fuctions that converts KB library name to manufacturer name */
static ADC_TypeDef *_get_device(adc_device_t dev);
static uint32_t _get_channel(adc_ch_t ch);
/* Peripheral clock function */
static void _enable_adc_clk(adc_device_t dev);
/******************************************************************************
* Public API Functions
******************************************************************************/
/* Initialization functions */
int adc_init(adc_t *obj, adc_init_t *settings)
{
ADC_ChannelConfTypeDef sConfig;
/* Configure the ADC peripheral */
obj->handler.Instance = _get_device(settings->device);
/* De-initialize before initialization */
if (HAL_ADC_DeInit(&obj->handler) != HAL_OK) {
/* ADC de-initialization Error */
KB_DEBUG_ERROR("device de-initialization error!\r\n");
return KB_ERROR;
}
/* Initialize ADC hardware */
// Enable ADC Clock first
_enable_adc_clk(settings->device);
// Asynchronous clock mode, input ADC clock not divided
obj->handler.Init.ClockPrescaler = ADC_CLOCKPRESCALER_PCLK_DIV4;
// 12-bit resolution for converted data
obj->handler.Init.Resolution = ADC_RESOLUTION_12B;
// Right-alignment for converted data
obj->handler.Init.DataAlign = ADC_DATAALIGN_RIGHT;
// Sequencer disabled (ADC conversion on only 1 channel: channel set on rank 1)
obj->handler.Init.ScanConvMode = DISABLE;
// EOC flag picked-up to indicate conversion end
obj->handler.Init.EOCSelection = DISABLE;
// Continuous mode disabled to have only 1 conversion at each conversion trig
obj->handler.Init.ContinuousConvMode = DISABLE;
// Parameter discarded because sequencer is disabled
obj->handler.Init.NbrOfConversion = 1;
// Parameter discarded because sequencer is disabled
obj->handler.Init.DiscontinuousConvMode = DISABLE;
// Parameter discarded because sequencer is disabled
obj->handler.Init.NbrOfDiscConversion = 0;
// Software start to trig the 1st conversion manually, without external event
obj->handler.Init.ExternalTrigConv = ADC_EXTERNALTRIGCONV_T1_CC1;
// Parameter discarded because software trigger chosen
obj->handler.Init.ExternalTrigConvEdge = ADC_EXTERNALTRIGCONVEDGE_NONE;
// DMA one-shot mode selected (not applied to this example)
obj->handler.Init.DMAContinuousRequests = DISABLE;
if (HAL_ADC_Init(&obj->handler) != HAL_OK) {
/* ADC initialization Error */
KB_DEBUG_ERROR("device initialization error!\r\n");
return KB_ERROR;
}
/* Configure ADC regular channel */
// Sampled channel number
sConfig.Channel = _get_channel(settings->channel);
// Rank of sampled channel
sConfig.Rank = 1;
// Sampling time (number of clock cycles unit)
sConfig.SamplingTime = ADC_SAMPLETIME_3CYCLES;
// Parameter discarded because offset correction is disabled
sConfig.Offset = 0;
if (HAL_ADC_ConfigChannel(&obj->handler, &sConfig) != HAL_OK) {
/* Channel Configuration Error */
KB_DEBUG_ERROR("Channel configuration Error!\r\n");
return KB_ERROR;
}
/* Creating mutex */
#if KB_USE_PERIPHERAL_FREERTOS_LOCK
obj->lock = xSemaphoreCreateMutex();
if(obj->lock == NULL) {
/* Mutex creating Error */
KB_DEBUG_ERROR("device mutex creation error!\r\n");
return KB_ERROR;
}
#endif
return KB_OK;
}
/* Configuration functions */
int adc_pin(gpio_port_t port, gpio_pin_t pin)
{
/* Enable GPIO clock */
gpio_enable_clk(port);
/* ADC Channel GPIO pin configuration */
gpio_init_t gpio_setting = {
.Mode = GPIO_MODE_ANALOG,
.Pull = NOPULL,
.Speed = GPIO_SPEED_FREQ_VERY_HIGH // 50MHz
};
gpio_init(port, pin, &gpio_setting);
return KB_OK;
}
/* Operation functions */
uint32_t adc_measure(adc_t *obj)
{
/*##-3- Start the conversion process #######################################*/
if (HAL_ADC_Start(&obj->handler) != HAL_OK) {
/* Start Conversation Error */
Error_Handler();
}
/*##-4- Wait for the end of conversion #####################################*/
/* Before starting a new conversion, you need to check the current state of
the peripheral; if it�s busy you need to wait for the end of current
conversion before starting a new one.
For simplicity reasons, this example is just waiting till the end of the
conversion, but application may perform other tasks while conversion
operation is ongoing. */
if (HAL_ADC_PollForConversion(&obj->handler, 10) != HAL_OK) {
/* End Of Conversion flag not set on time */
Error_Handler();
}
/* Check if the continuous conversion of regular channel is finished */
if ((HAL_ADC_GetState(&obj->handler) & HAL_ADC_STATE_EOC_REG) == HAL_ADC_STATE_EOC_REG) {
/*##-5- Get the converted value of regular channel ########################*/
return HAL_ADC_GetValue(&obj->handler);
}
KB_DEBUG_ERROR("Conversion error!\r\n");
return KB_ERROR;
}
/******************************************************************************
* Private Functions
******************************************************************************/
static ADC_TypeDef *_get_device(adc_device_t dev)
{
static ADC_TypeDef *const _device_table[] = {
ADC1, ADC2, ADC3
};
return _device_table[(int)dev];
}
static uint32_t _get_channel(adc_ch_t ch)
{
static const uint32_t _channel_table[] = {
ADC_CHANNEL_0, ADC_CHANNEL_1, ADC_CHANNEL_2, ADC_CHANNEL_3, ADC_CHANNEL_4,
ADC_CHANNEL_5, ADC_CHANNEL_6, ADC_CHANNEL_7, ADC_CHANNEL_8, ADC_CHANNEL_9,
ADC_CHANNEL_10, ADC_CHANNEL_11, ADC_CHANNEL_12, ADC_CHANNEL_13,
ADC_CHANNEL_14, ADC_CHANNEL_15
};
return _channel_table[(int)ch];
}
static void _enable_adc_clk (adc_device_t dev)
{
switch (dev) {
case KB_ADC1:
__ADC1_CLK_ENABLE();
break;
case KB_ADC2:
__ADC2_CLK_ENABLE();
break;
case KB_ADC3:
__ADC3_CLK_ENABLE();
break;
default:
KB_DEBUG_ERROR("Wrong ADC device selected!\r\n");
}
return;
}