The Execute Pipeline
====================
.. _dual-issue-pipeline:
.. figure:: /figures/execution-pipeline-2w.png
:alt: Dual Issue Pipeline
An example pipeline for a dual-issue BOOM. The first issue port schedules Micro-Ops onto
Execute Unit #0, which can accept ALU operations, FPU operations, and integer multiply instructions.
The second issue port schedules ALU operations, integer divide instructions (unpipelined), and load/store
operations. The ALU operations can bypass to dependent instructions. Note that the ALU in EU#0 is
padded with pipeline registers to match latencies with the FPU and iMul units to make scheduling for the
write-port trivial. Each Execution Unit has a single issue-port dedicated to it but contains within it a number
of lower-level Functional Units.
The Execution Pipeline covers the execution and write-back of Micro-Ops.
Although the Micro-Ops will travel down the pipeline one after the other
(in the order they have been issued), the Micro-Ops themselves are
likely to have been issued to the Execution Pipeline out-of-order.
:numref:`dual-issue-pipeline` shows an example Execution Pipeline for a
dual-issue BOOM.
Execution Units
---------------
.. _example-fu:
.. figure:: /figures/execution-unit.png
:alt: Example Execution Unit
An example Execution Unit. This particular example shows an integer ALU (that can bypass
results to dependent instructions) and an unpipelined divider that becomes busy during operation. Both
functional units share a single write-port. The Execution Unit accepts both kill signals and branch resolution
signals and passes them to the internal functional units as required.
An Execution Unit is a module that a single issue port will schedule
Micro-Ops onto and contains some mix of functional units. Phrased in
another way, each issue port from the Issue Queue talks to one and only
one Execution Unit. An Execution Unit may contain just a single simple
integer ALU, or it could contain a full complement of floating point
units, a integer ALU, and an integer multiply unit.
The purpose of the Execution Unit is to provide a flexible abstraction
which gives a lot of control over what kind of Execution Units the
architect can add to their pipeline
Scheduling Readiness
~~~~~~~~~~~~~~~~~~~~
An Execution Unit provides a bit-vector of the functional units it has
available to the issue scheduler. The issue scheduler will only schedule
Micro-Ops that the Execution Unit supports. For functional units that
may not always be ready (e.g., an un-pipelined divider), the appropriate
bit in the bit-vector will be disabled (See :numref:`dual-issue-pipeline`).
Functional Units
----------------
.. _abstract-fu:
.. figure:: /figures/abstract-functional-unit.png
:alt: Abstract Functional Unit
The abstract Pipelined Functional Unit class. An expert-written, low-level functional unit
is instantiated within the Functional Unit. The request and response ports are abstracted and bypass and
branch speculation support is provided. Micro-Ops are individually killed by gating off their response as they
exit the low-level functional unit.
Functional units are the muscle of the CPU, computing the necessary
operations as required by the instructions. Functional units typically
require a knowledgable domain expert to implement them correctly and
efficiently.
For this reason, BOOM uses an abstract Functional Unit class to “wrap"
expert-written, low-level functional units from the Rocket repository
(see :ref:`The Rocket-Chip Repository`). However, the expert-written functional units
created for the Rocket in-order processor make assumptions about
in-order issue and commit points (namely, that once an instruction has
been dispatched to them it will never need to be killed). These
assumptions break down for BOOM.
However, instead of re-writing or forking the functional units, BOOM
provides an abstract Functional Unit class (see :numref:`abstract-fu`)
that “wraps" the lower-level functional
units with the parameterized auto-generated support code needed to make
them work within BOOM. The request and response ports are abstracted,
allowing Functional Units to provide a unified, interchangeable
interface.
Pipelined Functional Units
~~~~~~~~~~~~~~~~~~~~~~~~~~
A pipelined functional unit can accept a new Micro-Op every cycle. Each
Micro-Op will take a known, fixed latency.
Speculation support is provided by auto-generating a pipeline that
passes down the Micro-Op meta-data and *branch mask* in parallel with
the Micro-Op within the expert-written functional unit. If a Micro-Op is
misspeculated, it’s response is de-asserted as it exits the functional
unit.
An example pipelined functional unit is shown in :numref:`abstract-fu`.
Un-pipelined Functional Units
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Un-pipelined functional units (e.g., a divider) take an variable (and
unknown) number of cycles to complete a single operation. Once occupied,
they de-assert their ready signal and no additional Micro-Ops may be
scheduled to them.
Speculation support is provided by tracking the *branch mask* of the
Micro-Op in the functional unit.
The only requirement of the expert-written un-pipelined functional unit
is to provide a *kill* signal to quickly remove misspeculated
Micro-Ops. [1]_
.. _fu-hierarchy:
.. figure:: /figures/functional-unit-hierarchy.png
:alt: Functional Unit Hierarchy
The dashed ovals are the low-level functional units written by experts, the squares are
concrete classes that instantiate the low-level functional units, and the octagons are abstract classes that
provide generic speculation support and interfacing with the BOOM pipeline. The floating point divide
and squart-root unit doesn’t cleanly fit either the Pipelined nor Unpipelined abstract class, and so directly
inherits from the FunctionalUnit super class.
Branch Unit & Branch Speculation
--------------------------------
The Branch Unit handles the resolution of all branch and jump
instructions.
All Micro-Ops that are “inflight" in the pipeline (have an allocated ROB
entry) are given a *branch mask*, where each bit in the *branch mask*
corresponds to an un-executed, inflight branch that the Micro-Op is
speculated under. Each branch in *Decode* is allocated a *branch tag*,
and all following Micro-Ops will have the corresponding bit in the
*branch mask* set (until the branch is resolved by the Branch Unit).
If the branches (or jumps) have been correctly speculated by the
Front-end, then the Branch Unit’s only action is to broadcast the
corresponding branch tag to *all* inflight Micro-Ops that the branch has
been resolved correctly. Each Micro-Op can then clear the corresponding
bit in its *branch mask*, and that branch tag can then be allocated to a
new branch in the *Decode* stage.
If a branch (or jump) is misspeculated, the Branch Unit must redirect
the PC to the correct target, kill the Front-end and fetch buffer, and
broadcast the misspeculated *branch tag* so that all dependent, inflight
Micro-Ops may be killed. The PC redirect signal goes out immediately, to
decrease the misprediction penalty. However, the *kill* signal is
delayed a cycle for critical path reasons.
The Front-end must pass down the pipeline the appropriate branch
speculation meta-data, so that the correct direction can be reconciled
with the prediction. Jump Register instructions are evaluated by
comparing the correct target with the PC of the next instruction in the
ROB (if not available, then a misprediction is assumed). Jumps are
evaluated and handled in the Front-end (as their direction and target
are both known once the instruction can be decoded).
BOOM (currently) only supports having one Branch Unit.
Load/Store Unit
---------------
The Load/Store Unit (LSU) handles the execution of load, store, atomic,
and fence operations.
BOOM (currently) only supports having one LSU (and thus can only send
one load or store per cycle to memory). [2]_
See `The Load/Store Unit (LSU)` for more details on the LSU.
Floating Point Units
--------------------
.. _fp-fu:
.. figure:: /figures/functional-unit-fpu.png
:alt: Functional Unit for FPU
The class hierarchy of the FPU is shown. The expert-written code is contained within
the hardfloat and rocket repositories. The “FPU” class instantiates the Rocket components, which itself
is further wrapped by the abstract Functional Unit classes (which provides the out-of-order speculation
support).
The low-level floating point units used by BOOM come from the Rocket
processor (https://github.com/freechipsproject/rocket-chip) and hardfloat
(https://github.com/ucb-bar/berkeley-hardfloat) repositories. Figure
:numref:`fp-fu` shows the class hierarchy of the FPU.
To make the scheduling of the write-port trivial, all of the pipelined
FP units are padded to have the same latency. [3]_
Floating Point Divide and Square-root Unit
------------------------------------------
BOOM fully supports floating point divide and square-root operations
using a single **FDiv/Sqrt** (or **fdiv** for short). BOOM accomplishes this by
instantiating a double-precision unit from the hardfloat repository. The
unit comes with the following features/constraints:
- expects 65-bit recoded double-precision inputs
- provides a 65-bit recoded double-precision output
- can execute a divide operation and a square-root operation
simultaneously
- operations are unpipelined and take an unknown, variable latency
- provides an *unstable* FIFO interface
Single-precision operations have their operands upscaled to
double-precision (and then the output downscaled). [4]_
Although the unit is unpipelined, it does not fit cleanly into the
Pipelined/Unpipelined abstraction used by the other functional units
(see :numref:`fu-hierarchy`). This is because the unit provides
an unstable FIFO interface: although the unit may provide a *ready*
signal on Cycle i, there is no guarantee that it will continue
to be *ready* on Cycle i+1, even if no operations are enqueued.
This proves to be a challenge, as the Issue Queue may attempt to issue
an instruction but cannot be certain the unit will accept it once it
reaches the unit on a later cycle.
The solution is to add extra buffering within the unit to hold
instructions until they can be released directly into the unit. If the
buffering of the unit fills up, back pressure can be safely applied to
the Issue Queue. [5]_
Parameterization
----------------
BOOM provides flexibility in specifying the issue width and the mix of
functional units in the execution pipeline. :numref:`parameterization-exe-unit` shows
how to instantiate an execution pipeline in BOOM.
.. _parameterization-exe-unit:
.. code-block:: scala
:caption: Instantiating the Execution Pipeline (in dpath.scala). Adding execution units is as simple as instantiating another ExecutionUnit module and adding it to the exe units ArrayBuffer.
val exe_units = ArrayBuffer[ExecutionUnit]()
if (ISSUE_WIDTH == 2)
{
exe_units += Module(new ALUExeUnit(is_branch_unit = true
, has_mul = true
))
exe_units += Module(new ALUMemExeUnit(has_div = true
))
}
else if (ISSUE_WIDTH == 3)
{
exe_units += Module(new ALUExeUnit(is_branch_unit = true
, has_mul = true
))
exe_units += Module(new ALUExeUnit(has_div = true))
exe_units += Module(new MemExeUnit())
}
Additional parameterization, regarding things like the latency of the FP
units can be found within the Configuration settings (configs.scala).
Control/Status Register Instructions
------------------------------------
A set of Control/Status Register (CSR) instructions allow the atomic
read and write of the Control/Status Registers. These architectural
registers are separate from the integer and floating registers, and
include the cycle count, retired instruction count, status, exception
PC, and exception vector registers (and many more!). Each CSR has its
own required privilege levels to read and write to it and some have
their own side-effects upon reading (or writing).
BOOM (currently) does not rename *any* of the CSRs, and in addition to
the potential side-effects caused by reading or writing a CSR, **BOOM
will only execute a CSR instruction non-speculatively.** [6]_ This is
accomplished by marking the CSR instruction as a “unique" (or
“serializing") instruction - the ROB must be empty before it may proceed
to the Issue Queue (and no instruction may follow it until it has
finished execution and been committed by the ROB). It is then issued by
the Issue Queue, reads the appropriate operands from the Physical
Register File, and is then sent to the CSRFile. [7]_ The CSR instruction
executes in the CSRFile and then writes back data as required to the
Physical Register File. The CSRFile may also emit a PC redirect and/or
an exception as part of executing a CSR instruction (e.g., a syscall).
.. [1]
This constraint could be relaxed by waiting for the un-pipelined unit
to finish before de-asserting its busy signal and suppressing the
*valid* output signal.
.. [2]
Relaxing this constraint could be achieved by allowing multiple LSUs
to talk to their own bank(s) of the data-cache, but the added
complexity comes in allocating entries in the LSU before knowing the
address, and thus which bank, a particular memory operation pertains
to.
.. [3]
Rocket instead handles write-port scheduling by killing and
refetching the offending instruction (and all instructions behind it)
if there is a write-port hazard detected. This would be far more
heavy-handed to do in BOOM.
.. [4]
It is cheaper to perform the SP-DP conversions than it is to
instantiate a single-precision fdivSqrt unit.
.. [5]
It is this ability to hold multiple inflight instructions within the
unit simultaneously that breaks the “only one instruction at a time"
assumption required by the UnpipelinedFunctionalUnit abstract class.
.. [6]
There is a lot of room to play with regarding the CSRs. For example,
it is probably a good idea to rename the register (dedicated for use
by the supervisor) as it may see a lot of use in some kernel code and
it causes no side-effects.
.. [7]
The CSRFile is a Rocket component.
The Rocket Custom Co-Processor Interface (RoCC)
-----------------------------------------------
The ROCC interface accepts a ROCC command and up to two register inputs
from the Control Processor’s scalar register file. The ROCC command is
actually the entire RISC-V instruction fetched by the Control Processor
(a “ROCC instruction"). Thus, each ROCC queue entry is at least
2\*XPRLEN + 32 bits in size (additional ROCC instructions may use the
longer instruction formats to encode additional behaviors).
As BOOM does not store the instruction bits in the ROB, a separate data
structure (A “ROCC Shim") holds the
instructions until the ROCC instruction can be committed and the ROCC
command sent to the co-processor.
The source operands will also require access to BOOM’s register file.
ROCC instructions are dispatched to the Issue Window, and scheduled
so that they may access the read ports of the register file once the
operands are available. The operands are then written into the ROCC
Shim, which stores the operands and the instruction
bits until they can be sent to the co-processor. This requires
significant state.
After issue to RoCC, we track a queue of in-flight RoCC instructions,
since we need to translate the logical destination register identifier
from the RoCC response into the previously renamed physical destination
register identifier.
Currently the RoCC interface does not support interrupts, exceptions,
reusing the BOOM FPU, or direct access to the L1 data cache. This should
all be straightforward to add, and will be completed as demand arises.