Calibration
===========
We need to calibrate each TriPoint module to account for unique TX and RX
delays with DW1000 radios.
Process
-------
The TriPoint software includes the code needed to run calibration. Putting
the node in calibration mode requires writing the calibration node index
to the `0x3159` characteristic.
In practice, do this:
1. Make noble run without sudo:
sudo setcap cap_net_raw+eip node_modules/noble/build/Release/hci-ble
2. Collect the data from each node:
node ./calibration_log.js
Make sure there are only 3 nodes on during calibration.
3. Process the data into a single file
./calibration_condense.py YYYY-MM-DD_HH-MM-SS