Loading files
3d097a032This file is pinned to the selected release. Download the original to open it in your design tool.
// Copyright (c) 1999-2014 OPEN CASCADE SAS
//
// This file is part of Open CASCADE Technology software library.
//
// This library is free software; you can redistribute it and/or modify it under
// the terms of the GNU Lesser General Public License version 2.1 as published
// by the Free Software Foundation, with special exception defined in the file
// OCCT_LGPL_EXCEPTION.txt. Consult the file LICENSE_LGPL_21.txt included in OCCT
// distribution for complete text of the license and disclaimer of any warranty.
//
// Alternatively, this file may be used under the terms of Open CASCADE
// commercial license or contractual agreement.
// gka 05.03.99 S4134 upgrade from CD to DIS
#include <Interface_Check.hxx>
#include <Interface_EntityIterator.hxx>
#include <Interface_MSG.hxx>
#include "RWStepBasic_RWUncertaintyMeasureWithUnit.pxx"
#include <StepBasic_MeasureValueMember.hxx>
#include <StepBasic_UncertaintyMeasureWithUnit.hxx>
#include <StepData_StepReaderData.hxx>
#include <StepData_StepWriter.hxx>
//=================================================================================================
RWStepBasic_RWUncertaintyMeasureWithUnit::RWStepBasic_RWUncertaintyMeasureWithUnit() = default;
//=================================================================================================
void RWStepBasic_RWUncertaintyMeasureWithUnit::ReadStep(
const occ::handle<StepData_StepReaderData>& data,
const int num,
occ::handle<Interface_Check>& ach,
const occ::handle<StepBasic_UncertaintyMeasureWithUnit>& ent) const
{
if (data->IsComplex(num))
{
ach->AddWarning("Complex Type not allowed, only suitable values are read");
// CATIA ecrit des trucs complexes, comme suit :
// LENGTH_MEASURE_WITH_UNIT ()
// MEASURE_WITH_UNIT (LENGTH_MEASURE(val),#..)
// UNCERTAINTY_MEASURE_WITH_UNIT ('str1','str2')
// -> c est illicite, LENGTH_MEASURE est un invite importun
// On relit en ignorant ce terme
// REMARQUE : le ReadWriteModule a deja fait le filtrage des types
// LENGTH_MEASURE_WITH_UNIT : on passe
int num1 = num;
// MEASURE_WITH_UNIT
num1 = data->NextForComplex(num1);
if (!data->CheckNbParams(num1, 2, ach, "measure_with_unit"))
{
return;
}
// --- inherited field : valueComponent ---
occ::handle<StepBasic_MeasureValueMember> mvc = new StepBasic_MeasureValueMember;
data->ReadMember(num1, 1, "value_component", ach, mvc);
// --- inherited field : unitComponent ---
StepBasic_Unit aUnitComponent;
data->ReadEntity(num1, 2, "unit_component", ach, aUnitComponent);
// UNCERTAINTY_MEASURE_WITH_UNIT (ce qu il en reste !)
num1 = data->NextForComplex(num1);
if (!data->CheckNbParams(num1, 2, ach, "uncertainty_measure_with_unit"))
{
return;
}
// --- own field : name ---
occ::handle<TCollection_HAsciiString> aName;
data->ReadString(num1, 1, "name", ach, aName);
// --- own field : description ---
occ::handle<TCollection_HAsciiString> aDescription;
if (data->IsParamDefined(num1, 2))
{ // gka 05.03.99 S4134 upgrade from CD to DIS
data->ReadString(num1, 2, "description", ach, aDescription);
}
// Ca yest, on peut faire l init
ent->Init(mvc, aUnitComponent, aName, aDescription);
return;
}
// --- Number of Parameter Control ---
if (!data->CheckNbParams(num, 4, ach, "uncertainty_measure_with_unit"))
{
return;
}
// --- inherited field : valueComponent ---
// double aValueComponent;
// bool stat1;
// stat1 = data->ReadReal (num,1,"value_component",ach,aValueComponent);
// --- Update 12-02-96 by FMA => 31-MAR-1997 by CKY
occ::handle<StepBasic_MeasureValueMember> mvc = new StepBasic_MeasureValueMember;
data->ReadMember(num, 1, "value_component", ach, mvc);
// --- inherited field : unitComponent ---
StepBasic_Unit aUnitComponent;
data->ReadEntity(num, 2, "unit_component", ach, aUnitComponent);
// --- own field : name ---
occ::handle<TCollection_HAsciiString> aName;
data->ReadString(num, 3, "name", ach, aName);
// --- own field : description ---
occ::handle<TCollection_HAsciiString> aDescription;
data->ReadString(num, 4, "description", ach, aDescription);
//--- Initialisation of the read entity ---
ent->Init(mvc, aUnitComponent, aName, aDescription);
}
//=================================================================================================
void RWStepBasic_RWUncertaintyMeasureWithUnit::WriteStep(
StepData_StepWriter& SW,
const occ::handle<StepBasic_UncertaintyMeasureWithUnit>& ent) const
{
// --- inherited field valueComponent ---
// Update 12-02-96 by FMA
// The Value shall be Typed - LENGTH_MEASURE, PLANE_ANGLE_MEASURE,
// SOLID_ANGLE_MEASURE
// The actual state is LENGTH_MEASURE ONLY
// UPDATE to be done later but mandatory
// char lm[100],lmv[50];
// Interface_FloatWriter::Convert
// (Interface_MSG::Intervalled(ent->ValueComponent()*0.98,5,true),
// lmv,true, 10.,0.1,"%E","%E");
// Sprintf (lm,"LENGTH_MEASURE(%s)",lmv);
// SW.SendString(lm);
// SW.AddString("LENGTH_MEASURE");
// SW.OpenSub();
// UPDATE 31-MARS-1997 by CKY : ca devrait etre bon desormais
SW.Send(ent->ValueComponentMember());
// SW.CloseSub();
// --- inherited field unitComponent ---
SW.Send(ent->UnitComponent().Value());
// --- own field : name ---
SW.Send(ent->Name());
// --- own field : description ---
SW.Send(ent->Description());
}
//=================================================================================================
void RWStepBasic_RWUncertaintyMeasureWithUnit::Share(
const occ::handle<StepBasic_UncertaintyMeasureWithUnit>& ent,
Interface_EntityIterator& iter) const
{
iter.GetOneItem(ent->UnitComponent().Value());
}