Loading files
This file is pinned to the selected release. Download the original to open it in your design tool.
c7b52106bThis file is pinned to the selected release. Download the original to open it in your design tool.
{
"schema_version": 1,
"supported_konnect_version": "0.12.1",
"companion_revision": 2,
"enhancements": [
{
"id": "agent-delegation",
"status": "active",
"reason": "Complete builds and final reviews need deterministic use of the installed Codex agents.",
"evidence": ["Konnect safe-parts benchmark, Discussion #239"],
"introduced_for": "0.6.0",
"retire_when": "Konnect supplies equivalent Codex-native delegation policy.",
"assertions": [
{
"target": "skills/konnect-codex/SKILL.md",
"contains": "Delegate a complete schematic build"
}
]
},
{
"id": "schematic-evidence-and-collision-gate",
"status": "active",
"reason": "Valid direct labels can be reported as orphaned, while adjacent automatic stubs can collide and short distinct nets.",
"evidence": ["Konnect safe-parts benchmark, Discussion #239"],
"introduced_for": "0.6.0",
"retire_when": "The orphan checker recognizes valid pin-end labels and automatic stub placement prevents collisions.",
"assertions": [
{
"target": "skills/kicad-schematic/SKILL.md",
"contains": "solely to clear an orphan finding"
},
{
"target": "agents/konnect_schematic_builder.toml",
"contains": "a clean result completes that wiring step"
}
]
},
{
"id": "schematic-layout-readability-gate",
"status": "active",
"reason": "Generated schematics can be electrically valid but unusable by humans when components, labels, fields, and support parts are scattered, overlapping, or connected only by labels that hide local passive topology.",
"evidence": [
"AI-assisted schematic readability prior-art research on 2026-08-21",
"User-reported Konnect schematic readability failures on 2026-08-21"
],
"introduced_for": "0.7.0",
"retire_when": "Konnect supplies an equivalent schematic layout/readability gate with block grouping, visible local passive wiring, label-inclusive overlap checks, structured acceptance evidence, independent review, rendered inspection, and block-level re-layout.",
"assertions": [
{
"target": "skills/kicad-schematic/SKILL.md",
"contains": "group and tag each"
},
{
"target": "skills/kicad-schematic/references/schematic-layout-acceptance.md",
"contains": "Component-only grouping is not full grouping"
},
{
"target": "skills/kicad-schematic/references/schematic-layout-acceptance.md",
"contains": "Local passive networks must visibly explain"
},
{
"target": "skills/kicad-schematic/references/functional-block-relocation.md",
"contains": "Treat block movement as a managed reconstruction"
},
{
"target": "skills/kicad-schematic/references/functional-block-relocation.md",
"contains": "MANAGED_CLOSURE"
},
{
"target": "agents/konnect_schematic_builder.toml",
"contains": "group-closure evidence"
},
{
"target": "agents/konnect_schematic_builder.toml",
"contains": "Hand-wire the passive networks"
},
{
"target": "agents/konnect_design_reviewer.toml",
"contains": "Require the schematic"
},
{
"target": "skills/kicad-review/references/design-checklist.md",
"contains": "Local passive networks are placed"
}
]
},
{
"id": "pcb-transfer-integrity",
"status": "active",
"reason": "A successful schematic-to-PCB transfer converted footprint graphics into phantom pads without reporting failure.",
"evidence": ["Konnect safe-parts benchmark, Discussion #239", "Konnect issue referencing PR #232"],
"introduced_for": "0.6.0",
"retire_when": "Konnect validates every transferred child layer and preserves footprint pad, graphic, and model counts.",
"assertions": [
{
"target": "skills/kicad-pcb/SKILL.md",
"contains": "PCB transfer integrity gate"
}
]
},
{
"id": "contradictory-verifier-gate",
"status": "active",
"reason": "Aggregate review and manufacturing tools reported success despite DRC errors, unrouted work, and implausible zero-pad coverage.",
"evidence": ["Konnect safe-parts benchmark, Discussion #239"],
"introduced_for": "0.6.0",
"retire_when": "Aggregate verdicts fail closed and expose complete, internally consistent coverage.",
"assertions": [
{
"target": "skills/kicad-review/SKILL.md",
"contains": "Contradiction gate"
},
{
"target": "skills/kicad-manufacture/SKILL.md",
"contains": "cannot override DRC errors"
},
{
"target": "agents/konnect_design_reviewer.toml",
"contains": "A passing aggregate verdict cannot override"
}
]
},
{
"id": "requirements-based-review-defaults",
"status": "active",
"reason": "Universal ESD, bulk-capacitance, fiducial, and per-pin decoupling requirements can misclassify designs without requirements or datasheet evidence.",
"evidence": ["Review of the Konnect 0.6.0 design-review agent"],
"introduced_for": "0.6.0",
"retire_when": "Upstream review guidance distinguishes hard requirements from context-dependent engineering defaults.",
"assertions": [
{
"target": "agents/konnect_design_reviewer.toml",
"contains": "Classify a finding as CRITICAL only when"
}
]
},
{
"id": "doctor-agent-reporting",
"status": "active",
"reason": "The health report said zero recognizable agents while two plugin-managed agents were installed.",
"evidence": ["konnect-codex doctor output on 2026-08-16"],
"introduced_for": "0.6.0",
"retire_when": "Plugin-owned and upstream-native agent counts remain separately visible.",
"assertions": []
},
{
"id": "native-auto-install-suppression",
"status": "retired",
"reason": "Konnect 0.6.1 through 0.10.0 silently reinstated native Codex skills on MCP startup. Konnect v0.11.0 makes startup non-mutating and moves installation to explicit `konnect init`.",
"evidence": ["Konnect issue #242", "Konnect v0.11.0 release and exact-tag source audit on 2026-08-29"],
"introduced_for": "0.6.1",
"retire_when": "Satisfied by Konnect v0.11.0. The companion retains only one-time cleanup for its legacy suppression marker.",
"assertions": []
},
{
"id": "pcb-builder-delegation",
"status": "active",
"reason": "The benchmark concentrated transfer, placement, routing, and zone work in the primary agent, leaving no deterministic specialist handoff between schematic construction and independent review.",
"evidence": ["Konnect safe-parts benchmark, Discussion #239", "Saved skills-enhancments.md recommendation from 2026-08-16"],
"introduced_for": "0.6.1",
"retire_when": "Konnect supplies an equivalent Codex-native PCB construction agent and deterministic schematic-to-PCB-to-review routing policy.",
"assertions": [
{
"target": "skills/konnect-codex/SKILL.md",
"contains": "Delegate complete schematic-to-PCB transfer"
},
{
"target": "agents/konnect_pcb_builder.toml",
"contains": "transfer inventory and comparison"
}
]
},
{
"id": "freerouting-first-routing",
"status": "active",
"reason": "Whole-board routing needs global obstacle avoidance, rip-up and retry, congestion management, and strict post-import acceptance; the selected route path must pass an executable compatibility preflight on the actual board.",
"evidence": ["DR2000 clock PCB benchmark on 2026-08-18", "Konnect v0.11.1 JLCPCB blinker benchmark on 2026-09-08", "Konnect issue #337"],
"introduced_for": "0.6.1",
"retire_when": "Konnect supplies equivalent first-class Codex guidance that selects the native pipeline and enforces route, revision, inventory, DRC, and cleanup acceptance gates.",
"assertions": [
{
"target": "skills/kicad-pcb/SKILL.md",
"contains": "Freerouting for whole-board routing"
},
{
"target": "skills/kicad-pcb/references/freerouting-workflow.md",
"contains": "Route acceptance"
},
{
"target": "agents/konnect_pcb_builder.toml",
"contains": "make Freerouting the default"
}
]
},
{
"id": "pcb-live-state-and-placement-gates",
"status": "active",
"reason": "A crashed PCB Editor produced stale trace queries and later mutations fell back to closed-file edits; routing also began while pads, test points, controls, and power components still overlapped.",
"evidence": ["DR2000 clock PCB benchmark on 2026-08-18"],
"introduced_for": "0.6.1",
"retire_when": "Konnect binds every PCB mutation to an explicit live-board identity, refuses mixed IPC/file phases, and exposes a placement readiness gate that blocks routing on mechanical and copper overlap.",
"assertions": [
{
"target": "skills/kicad-pcb/SKILL.md",
"contains": "Never mix live IPC and closed-file fallback"
},
{
"target": "agents/konnect_pcb_builder.toml",
"contains": "component positions, pad"
},
{
"target": "agents/konnect_design_reviewer.toml",
"contains": "stale-state contradiction"
}
]
},
{
"id": "custom-part-physical-pin-acceptance",
"status": "active",
"reason": "The DR2000 benchmark produced a visually plausible symbol and footprint with mirrored physical pins, which would make the assembled display nonfunctional.",
"evidence": ["DR2000 datasheet bottom-view correction on 2026-08-18"],
"introduced_for": "0.6.1",
"retire_when": "Konnect supplies a datasheet-view-aware symbol-to-pad acceptance workflow with independent physical pin-map evidence.",
"assertions": [
{"target": "skills/kicad-library/references/custom-part-acceptance.md", "contains": "Physical order and view"},
{"target": "agents/konnect_library_builder.toml", "contains": "physical clockwise/counter-clockwise order"}
]
},
{
"id": "visual-placement-checkpoint",
"status": "active",
"reason": "The DR2000 clock reached routing with overlapping test points and components that numeric placement output did not make sufficiently visible.",
"evidence": ["DR2000 clock PCB benchmark on 2026-08-18"],
"introduced_for": "0.6.1",
"retire_when": "Konnect exposes a placement-readiness result with rendered copper/courtyard evidence and blocks routing on unresolved overlap.",
"assertions": [
{"target": "skills/kicad-pcb/references/placement-acceptance.md", "contains": "2D board render"},
{"target": "agents/konnect_pcb_builder.toml", "contains": "visible checkpoint is accepted"}
]
},
{
"id": "offline-freerouting-bridge",
"status": "active",
"reason": "Konnect v0.12.1 exposes a revision-bound native route pipeline, but its Rust DSN preflight still rejects common KiCad roundrect and unnumbered NPTH pads before the optional native bridge is selected. The companion fallback preserves whole-board routing through KiCad's own DSN/SES APIs.",
"evidence": ["Konnect v0.11.1 JLCPCB blinker benchmark on 2026-09-08", "Konnect v0.11.1 specctra.rs supported pad profile", "Konnect v0.11.1 pcb_export.rs bridge-selection order"],
"introduced_for": "0.6.1",
"retire_when": "A released Konnect route passes a representative whole-board benchmark containing standard roundrect pads, unnumbered NPTH mechanical pads, official footprints, DSN export, routing, SES plan/apply, unchanged inventory, and direct DRC evidence.",
"assertions": [
{"target": "skills/kicad-pcb/references/freerouting-workflow.md", "contains": "konnect-codex freerouting route"},
{"target": "agents/konnect_pcb_builder.toml", "contains": "compatibility bridge"}
]
},
{
"id": "pcb-ownership-preflight",
"status": "active",
"reason": "Duplicate editors, wrong-board state, and IPC loss can redirect or stale PCB mutations; Codex's documented hook output does not currently provide a verified hard-denial contract.",
"evidence": ["Duplicate-open warning and IPC crash sessions on 2026-08-18", "Codex official documentation search on 2026-08-18"],
"introduced_for": "0.6.1",
"retire_when": "Konnect binds each mutation to an explicit board identity and Codex exposes a documented hard pre-tool denial contract or equivalent server-side guard.",
"assertions": [
{"target": "skills/kicad-pcb/SKILL.md", "contains": "pcb-preflight"}
]
},
{
"id": "eco-and-power-layout-branches",
"status": "active",
"reason": "A universal new-board flow does not preserve accepted routing during engineering changes or prove current, voltage-drop, thermal, and noisy-return requirements for motor and converter boards.",
"evidence": ["24 V motor-distribution board requirements", "DR2000 clock iterative layout experience"],
"introduced_for": "0.6.1",
"retire_when": "Konnect provides explicit ECO preservation and requirements-based power/thermal layout workflows.",
"assertions": [
{"target": "skills/kicad-pcb/references/eco-workflow.md", "contains": "affected nets"},
{"target": "skills/kicad-pcb/references/power-layout.md", "contains": "allowed voltage drop"}
]
},
{
"id": "firmware-bringup-handoff",
"status": "active",
"reason": "Manufacturing readiness alone does not preserve GPIO ownership, safe startup states, programming access, rail checks, and proof-of-life evidence for controller boards.",
"evidence": ["ESP32 DR2000 clock requirements", "Controller-board workflow review on 2026-08-18"],
"introduced_for": "0.6.1",
"retire_when": "Konnect supplies an equivalent Codex-native read-only firmware and controlled bring-up handoff.",
"assertions": [
{"target": "skills/kicad-bringup/SKILL.md", "contains": "reset/pull state"},
{"target": "agents/konnect_bringup_planner.toml", "contains": "READY FOR CONTROLLED BRING-UP"}
]
},
{
"id": "legacy-sourcing-and-review-evidence",
"status": "active",
"reason": "Legacy through-hole builds and benchmark reports need lifecycle/socket/assembly checks plus repeatable raw review artifacts, not only aggregate prose verdicts.",
"evidence": ["DR2000 and LA5041R-11B legacy component research", "Konnect benchmark discussion reporting"],
"introduced_for": "0.6.1",
"retire_when": "Konnect supplies lifecycle-aware manual-assembly guidance and a revisioned raw evidence package workflow.",
"assertions": [
{"target": "skills/kicad-manufacture/references/legacy-through-hole.md", "contains": "Socket part number"},
{"target": "skills/kicad-review/references/evidence-package.md", "contains": "raw ERC"}
]
},
{
"id": "evidence-grounded-review-methodology",
"status": "active",
"reason": "Readiness decisions need explicit design context, evidence basis, confidence, datasheet trust, review-limit disclosure, and revision deltas so aggregate output or missing checks are not presented as verified engineering conclusions.",
"evidence": [
"Konnect contradiction and evidence-package benchmarks",
"MIT-licensed kicad-happy review guidance: https://github.com/neusse/kicad-happy/tree/main/skills/kicad/references"
],
"introduced_for": "0.6.1",
"retire_when": "Konnect supplies equivalent Codex-native evidence classification, design-context calibration, datasheet trust gates, review-limit disclosure, and re-review status tracking.",
"assertions": [
{"target": "skills/kicad-review/references/review-methodology.md", "contains": "Not performed / review limits"},
{"target": "skills/kicad-review/SKILL.md", "contains": "severity, confidence, and one evidence"},
{"target": "agents/konnect_design_reviewer.toml", "contains": "fixed/still-open/new/waived/unverifiable"}
]
},
{
"id": "bom-lifecycle-workflow",
"status": "active",
"reason": "Manufacturing export guidance does not provide an end-to-end workflow for maintaining schematic BOM properties, qualifying MPNs and datasheets, evaluating alternates and lifecycle uncertainty, and verifying the resulting BOM export.",
"evidence": [
"Konnect 0.6.1 component-field, BOM-health, datasheet-enrichment, catalogue, and export tool contracts",
"MIT-licensed kicad-happy BOM guidance: https://github.com/neusse/kicad-happy/blob/main/skills/bom/SKILL.md"
],
"introduced_for": "0.6.1",
"retire_when": "Konnect supplies an equivalent Codex-native BOM qualification and lifecycle skill with source-of-truth, datasheet, alternate, time-sensitive evidence, and export acceptance gates.",
"assertions": [
{"target": "skills/kicad-bom/SKILL.md", "contains": "Schematic source of truth"},
{"target": "skills/kicad-bom/SKILL.md", "contains": "Stock, price, lead time"},
{"target": "skills/kicad-bom/SKILL.md", "contains": "native DNP"},
{"target": "skills/konnect-codex/SKILL.md", "contains": "library -> schematic -> BOM -> PCB"}
]
},
{
"id": "v0.10-feedback-acceptance-integration",
"status": "active",
"reason": "Konnect v0.12.1 supplies placement scores, explicit held-footprint feedback, guarded decoupling plans, deprecates the unsafe force-directed cleanup path, and supplies schematic visual baselines. Safe Codex execution still needs mechanical-lock planning, rejection of unexpected held sets, independent post-apply scoring, actual inline image inspection, and interpretation of intended visual drift.",
"evidence": [
"Konnect v0.11.1 kicad-pcb score-first and held-footprint guidance",
"Konnect v0.11.1 kicad-schematic visual feedback loop",
"konnect-codex placement and schematic readability acceptance gates"
],
"introduced_for": "0.10.0",
"retire_when": "Konnect's native Codex skills and agents require independent placement re-scoring, locked mechanical references, actual inline render inspection, and baseline drift interpretation with equivalent acceptance gates.",
"assertions": [
{"target": "skills/kicad-pcb/SKILL.md", "contains": "Score-first automation"},
{"target": "skills/kicad-schematic/SKILL.md", "contains": "compare_visual_baseline"},
{"target": "agents/konnect_pcb_builder.toml", "contains": "unexpected `held`"},
{"target": "agents/konnect_schematic_builder.toml", "contains": "intended edits also drift"}
]
},
{
"id": "v0.9-known-safety-gates",
"status": "active",
"reason": "Konnect v0.12.1 reconciles junctions for ordinary and batch symbol placement but still reports incomplete connectivity on bus entries and safely refuses connected moves. The v0.11 line fixed incomplete Default-netclass serialization and official footprint refresh.",
"evidence": [
"Konnect issues #315 and #328",
"Konnect v0.11.0 release notes and exact-tag source audit"
],
"introduced_for": "0.9.0",
"retire_when": "Issues #315 and #328 are fixed with KiCad round-trip evidence and the companion benchmark verifies the corrected contracts.",
"assertions": [
{"target": "skills/kicad-schematic/SKILL.md", "contains": "#328"},
{"target": "skills/kicad-schematic/SKILL.md", "contains": "Do not call `move_connected`"},
{"target": "agents/konnect_schematic_builder.toml", "contains": "v0.12.1 connectivity"}
]
},
{
"id": "verified-symbol-and-pin-guidance",
"status": "retired",
"reason": "Konnect v0.10.0 guidance contained invalid KiCad library IDs, reversed the Device:LED example, and stated unsafe universal physical pin rules. Konnect v0.11.0 corrects all three and adds asset tests.",
"evidence": [
"Konnect issue #356",
"Konnect v0.11.0 guidance diff and exact-tag asset tests reviewed on 2026-08-29"
],
"introduced_for": "0.10.0",
"retire_when": "Satisfied by Konnect v0.11.0. The corrected content remains in the reviewed Codex translation without being counted as a companion-only delta.",
"assertions": []
},
{
"id": "reference-reachability-and-evidence-contracts",
"status": "active",
"reason": "Installed references can be skipped when no parent skill links them, and agents/manufacturing guidance can otherwise report evidence or validation coverage their workflow never collected.",
"evidence": [
"Konnect issue #357",
"konnect-codex reference reachability and manufacturing-contract audit on 2026-08-28"
],
"introduced_for": "0.10.0",
"retire_when": "Upstream Codex-native guidance provides equivalent progressive disclosure, executable evidence contracts, and accurate released manufacturing behavior.",
"assertions": [
{"target": "skills/konnect-codex/SKILL.md", "contains": "unless its direct output is present"},
{"target": "agents/konnect_design_reviewer.toml", "contains": "rather than filling a success field from expectation"},
{"target": "skills/kicad-manufacture/SKILL.md", "contains": "does **not**"}
]
},
{
"id": "codex-hook-contract",
"status": "active",
"reason": "Codex PreToolUse guidance must be structured, safely installed, and accurate for live-only, fallback-capable, closed-board-only, and plan/apply PCB operations.",
"evidence": [
"Konnect issue #358 findings adapted to the Codex hook contract",
"Konnect v0.11.1 tool-directory runtime classifications",
"delete_graphics is live-or-closed fallback; set_predefined_sizes is closed-board-only"
],
"introduced_for": "0.10.0",
"retire_when": "Konnect provides an equivalent tested Codex-native hook contract and server-side ownership checks remain authoritative.",
"assertions": [
{"target": "hooks/hooks.json", "contains": "pre-pcb-closed"},
{"target": "hooks/hooks.json", "contains": "set_component_placements"}
]
},
{
"id": "guidance-governance-register",
"status": "active",
"reason": "Companion-only safety fixes and workflow improvements need an explicit retain/revise/retire decision on every Konnect release instead of relying on memory or blind prose merges.",
"evidence": [
"Konnect release-refresh history through v0.12.1",
"User requirement for a durable living change document on 2026-08-28"
],
"introduced_for": "0.10.0",
"retire_when": "The companion is no longer needed because upstream supplies equivalent first-class Codex skills, agents, hooks, governance, and tested release refresh behavior.",
"assertions": [
{"target": "docs/GUIDANCE_DELTA_REGISTER.md", "contains": "The required decision set is"},
{"target": "docs/GUIDANCE_STANDARDS.md", "contains": "This is the acceptance standard"}
]
},
{
"id": "explicit-workflow-routing",
"status": "active",
"reason": "Konnect exposes capable operations, but multi-stage success otherwise depends on prompt wording and the model independently reconstructing prerequisites, ordered phases, stop conditions, evidence, and handoffs.",
"evidence": [
"Custom-part and global-library workflow analysis on 2026-09-01",
"Repeated schematic-to-PCB, placement, routing, and manufacturing benchmark gaps"
],
"introduced_for": "0.11.0",
"retire_when": "Konnect supplies equivalent Codex-native discoverable workflow routing with ordered phases, stop conditions, direct evidence, and explicit completion outcomes.",
"assertions": [
{"target": "skills/kicad-workflows/SKILL.md", "contains": "Workflow selection gate"},
{"target": "skills/konnect-codex/SKILL.md", "contains": "`kicad-workflows`"},
{"target": "docs/GUIDANCE_DELTA_REGISTER.md", "contains": "`explicit-workflow-routing`"}
]
},
{
"id": "owned-process-lifecycle-cleanup",
"status": "active",
"reason": "KiCad, Freerouting, Java probes, and external helpers can survive a completed or failed workflow, block later IPC ownership, and tempt unsafe broad process termination unless ownership and cleanup are explicit.",
"evidence": [
"PIC16F88/HDLG-2416 PCB correction on 2026-09-01 left Freerouting windows and a headless Java --version child after the accepted board was saved",
"Repeated stale-process and duplicate-editor recovery during Konnect PCB benchmarks"
],
"introduced_for": "0.11.0",
"retire_when": "Konnect and the companion provide equivalent process ownership, bounded child cleanup, editor-session preservation, and end-of-workflow cleanup evidence across every external-tool path.",
"assertions": [
{"target": "skills/kicad-workflows/references/process-lifecycle.md", "contains": "Completion cleanup gate"},
{"target": "skills/kicad-workflows/SKILL.md", "contains": "process-lifecycle.md"},
{"target": "agents/konnect_pcb_builder.toml", "contains": "task-owned orphan"},
{"target": "docs/GUIDANCE_DELTA_REGISTER.md", "contains": "`owned-process-lifecycle-cleanup`"}
]
},
{
"id": "pcb-layout-physics-acceptance",
"status": "active",
"reason": "DRC and autorouter completion do not establish return-plane continuity, critical-loop geometry, current or thermal capacity, RF clearance, process-sensitive via feasibility, or production test access.",
"evidence": [
"11 PCB Layout Rules to NEVER Break transcript reviewed and calibrated against component, stackup, and fabricator requirements on 2026-09-03",
"Existing companion checks covered several individual concerns but did not require a routed-board applicability matrix or direct evidence package"
],
"introduced_for": "0.11.0",
"retire_when": "Konnect provides equivalent stackup-, datasheet-, and process-aware checks with direct evidence for every applicable layout-physics concern.",
"assertions": [
{"target": "skills/kicad-pcb/references/pcb-layout-physics-acceptance.md", "contains": "Reference-plane continuity"},
{"target": "skills/kicad-pcb/SKILL.md", "contains": "completed PCB-physics applicability/evidence matrix"},
{"target": "agents/konnect_pcb_builder.toml", "contains": "Every applicable PCB-layout-physics row"},
{"target": "agents/konnect_design_reviewer.toml", "contains": "PCB-layout-physics applicability matrix"},
{"target": "docs/GUIDANCE_DELTA_REGISTER.md", "contains": "`pcb-layout-physics-acceptance`"}
]
},
{
"id": "benchmark-ledger-completeness",
"status": "active",
"reason": "The v0.11.1 JLCPCB benchmark continued through routing failures while its durable ledger stopped at schematic acceptance, leaving the project record unable to establish the terminal outcome.",
"evidence": ["Konnect v0.11.1 JLCPCB blinker benchmark on 2026-09-08"],
"introduced_for": "0.11.1",
"retire_when": "The workflow runtime emits and validates equivalent gate-by-gate benchmark evidence and a terminal artifact inventory automatically.",
"assertions": [
{"target": "skills/kicad-workflows/SKILL.md", "contains": "Benchmark evidence"},
{"target": "docs/GUIDANCE_DELTA_REGISTER.md", "contains": "`benchmark-ledger-completeness`"}
]
}
]
}