Loading files
This file is pinned to the selected release. Download the original to open it in your design tool.
5c2804327This file is pinned to the selected release. Download the original to open it in your design tool.
# Per-hive vibration monitoring (BLE) — the ~20 Hz pre-swarm signal
> **The wired LIS3DH / LIS2DH12 accelerometer driver has been removed.** Earlier
> firmware carried an optional register-level driver (`ENABLE_LIS3DH_ACCEL`) for
> two accelerometers on the shared I2C bus at `0x18` / `0x19`. It was never part
> of the stock measurement path and is now gone entirely — there is no wired
> accelerometer support, and no `ENABLE_LIS3DH_ACCEL` flag. In-hive vibration
> comes **only from a paired BLE sensor**: a **HiveInside** node supplies full
> FFT bands, while a passive **HolyIot 25015 / RuuviTag** beacon (which cannot
> produce FFT bands) feeds a separate **low-rate** pre-swarm detector. See
> [holyiot-ble-sensor.md](holyiot-ble-sensor.md) and
> [hiveinside-ble-sensor.md](hiveinside-ble-sensor.md).
This document explains **why** vibration matters, **what** the `accel_*` fields
mean, and **how** the server evaluates them. The measurement fields and the
insight detectors are unchanged — only the source of the data moved from a wired
chip to a BLE sensor.
---
## Why measure vibration in addition to the microphones?
HiveHub can carry two INMP441 microphones (50–3000 Hz FFT bands). Vibration is
not a duplicate — it covers the **sub-audible band the microphones miss**, which
the literature identifies as the single most useful swarm-prediction signal.
The review *Uthoff, Nabhan Homsi & von Bergen (2023), "Acoustic and vibration
monitoring of honeybee colonies for beekeeping-relevant aspects of presence of
queen bee and swarming", Computers and Electronics in Agriculture 205:107589*
surveys the field and concludes (emphasis added):
> "Additionally, [Ramsey et al. (2020)] found that one of the frequencies that
> is potentially important for predicting swarming is at about **20 Hz and
> cannot be recorded by most microphones**. Thus, **including low-frequency
> accelerometers** into the setup may be a great way of **maximising the data
> quality**."
Key findings that motivate the vibration bands:
| Finding | Source (via the review) | Consequence for HiveHub |
|---|---|---|
| A ~**20 Hz** comb vibration is the strongest known **multi-day swarm predictor**; an alarm fired in >90 % of swarms and never on non-swarming hives | Ramsey et al. (2020), *Sci. Rep.* 10:9798 | Dedicated **8–30 Hz "swarm" band** + a rising-trend detector |
| The 20 Hz signal is **not captured by most microphones** (≈50 Hz floor) | Ramsey et al. (2020); review §4.5 | A vibration sensor, not a mic, is the right source for this band |
| Pre-swarm vibration **diverges 5–10 h to ~11 days before** the event | Bencsik et al. (2011) | Trend/baseline comparison over days, not an instantaneous threshold |
| Discrimination is **strongest at night (00:00–05:00)** | Ramsey et al. (2020); Woods (1959) | The detector compares **night-only** sub-series |
---
## What the `accel_*` fields mean
For each hive the paired BLE sensor reports the AC energy in three vibration
bands plus broadband stats, all in **milli-g (mg)** (a HiveInside node computes
these on-device from a high-rate capture; a HolyIot/RuuviTag beacon supplies
only a low-rate magnitude that feeds the low-rate detector, not the FFT bands):
| Field (`accel_{1,2}_…`) | Band | What it reflects |
|---|---|---|
| `band_swarm_mg` | **8 – 30 Hz** | Ramsey ~20 Hz **pre-swarm** vibration (headline) |
| `band_fanning_mg` | 30 – 100 Hz | Fanning / ventilation, low worker activity |
| `band_activity_mg` | 100 – 200 Hz | General in-comb worker activity / buzz fundamentals |
| `rms_mg` | broadband AC | Overall vibration level (gravity removed) |
| `peak_mg` | broadband AC | Largest single-sample deviation |
Diagnostics: `accel_{1,2}_ok` (sensor present & read), `sample_rate_hz`,
`sample_count`, `range_g`.
> The upper edge (200 Hz) is the Nyquist limit at a 400 Hz sampling rate. The
> queen-piping range (300–550 Hz) is deliberately **left to the microphone**'s
> `piping` band; the vibration bands concentrate on the low frequencies where
> they add new information.
> **Mounting matters.** For the substrate-borne signal to be usable, the sensor
> must be firmly coupled to the hive body or a brood frame — a sensor on flying
> leads mostly measures cable sway. Follow the literature: inner hive wall, or
> perpendicular to the comb in a brood frame.
---
## Server storage
The 18 `accel_*` fields (9 per hive) are accepted by `POST /api/v1/measurements`,
stored in dedicated columns on the `measurements` table, and returned by the
measurement read APIs. Fresh deployments get the columns from `init_db()`;
existing ones can apply
[`server/migrations/007_accelerometer_vibration.sql`](../server/migrations/007_accelerometer_vibration.sql)
(idempotent; also backfills from `raw_json`).
A missing/`!ok` sensor leaves the fields **null** rather than `0`, so the insight
detectors never mistake "no sensor" for "perfectly still hive".
---
## Auto-evaluation (insights)
The vibration data feeds two detectors in `server/insights.py` (see
[insights.md](insights.md) for the full catalogue):
1. **Pre-swarm vibration rising** (`detect_vibration_swarm_prediction`) — the
headline. In the active season it compares the **recent night-time** mean of
the 8–30 Hz band to a longer night-time baseline and fires a `swarm` /
`watch` alert when it has risen ≥ `VIBRATION_SWARM_STANDALONE_MULT` (2.0×),
with noise floors to avoid false positives on a near-still hive. Source:
Ramsey et al. (2020); Bencsik et al. (2011).
2. **Vibration boost to the temperature pre-swarm watch**
(`detect_pre_swarm_temp_instability`) — when the same night-time rise is
present (≥ `VIBRATION_SWARM_RISE_MULT`, 1.6×) it raises the confidence of the
existing temperature-based watch by up to +0.30 and notes the corroboration,
exactly like the microphone "piping" boost.
Both degrade gracefully: with no vibration source (or off-season) they simply
don't contribute, and every other detector is unchanged. Behavioural tests live
in [`test-data/test_accel_rules.py`](../test-data/test_accel_rules.py).
Thresholds (`VIBRATION_*` in `insights.py`) are conservative starting points —
recalibrate them against your own baseline once you have a season of data.
---
## Sources
- Uthoff, C., Nabhan Homsi, M. & von Bergen, M. (2023). *Acoustic and vibration
monitoring of honeybee colonies …* Computers and Electronics in Agriculture
205:107589.
- Ramsey, M.-T. et al. (2020). *The prediction of swarming in honeybee colonies
using vibrational spectra.* Scientific Reports 10:9798.
- Bencsik, M. et al. (2011). *Identification of the honey bee swarming process by
analysing the time course of hive vibrations.* Computers and Electronics in
Agriculture 76.
A broader TL;DR of the literature is in
[insights-sources-tldr.md](insights-sources-tldr.md).