"""Load-cell temperature compensation — pure, database-free logic.
HX711/load-cell readings drift with temperature: the bridge resistance and the
mechanical structure both change with ambient temperature, so an *unchanged*
physical load is reported as a slowly varying weight. On a beehive that drift
masquerades as nectar income at midday and as consumption overnight.
The firmware already ships everything needed to correct this after the fact —
every measurement carries the raw load-cell weight *and* an ambient temperature
(``ambient_temp_c`` from the SHT4x, plus the two DS18B20 hive probes). We keep
the raw values untouched in the database and apply a first-order correction on
read, using a per-device, per-scale coefficient. Because the raw data is never
mutated, the coefficient can be re-tuned (or disabled) at any time without
losing anything.
Model
-----
A first-order (linear) correction around a reference temperature::
compensated_kg = raw_kg - coeff_kg_per_c * (temp_c - ref_temp_c)
* ``coeff_kg_per_c`` is the observed drift of the *reported* weight per °C.
Positive means the scale reads heavier as it warms; we subtract that drift.
* ``ref_temp_c`` is the temperature at which the correction is zero — i.e. the
temperature the compensated reading is normalized to. Picking the mean
temperature of the calibration window keeps the correction centered and small.
The coefficient is expressed directly in **kg per °C** (not ppm/°C of span) so
it applies to the stored kilogram value without needing to know the cell's
full-scale span. Typical strain-gauge cells drift on the order of a few grams
per °C, but measuring your own from logged data (see :func:`fit_temp_coefficient`)
beats any datasheet number.
These functions are deliberately free of FastAPI/psycopg imports so they can be
unit-tested with no database or server (see test-data/test_tempcomp.py).
"""
from __future__ import annotations
from typing import Iterable, Optional
# Temperature field a coefficient may be keyed against. "ambient" (SHT4x) is the
# sensible default — it tracks the cell body closely in steady state. The hive
# probes are offered for setups where the cell sits inside the hive thermal mass.
VALID_TEMP_SOURCES = ("ambient", "hive_1", "hive_2")
# Field name in a measurement dict for each temperature source.
TEMP_SOURCE_FIELD = {
"ambient": "ambient_temp_c",
"hive_1": "hive_1_temp_c",
"hive_2": "hive_2_temp_c",
}
# Defaults mirrored by the device_configs columns / DeviceConfig model.
DEFAULT_REF_TEMP_C = 20.0
DEFAULT_TEMP_SOURCE = "ambient"
# EMA smoothing factor for temperature before applying compensation.
# alpha=1.0 disables smoothing (raw temperature); lower values smooth more.
# At a 10-minute measurement interval, 0.3 gives roughly a 20-minute time
# constant — enough to damp sunrise/sunset transients without lagging badly.
DEFAULT_EMA_ALPHA = 0.3
def ema_temperatures(
temps: list,
alpha: float = DEFAULT_EMA_ALPHA,
) -> list:
"""Exponential moving average over a temperature sequence.
Smooths the temperature series fed to compensate_weight so that fast
transients (sunrise, direct sun on the enclosure) don't produce a spike in
the corrected weight. None values pass through unchanged; the EMA state
carries forward across them using the last known value.
alpha in (0, 1]: 1.0 = no smoothing, smaller = heavier smoothing.
"""
smoothed: list = []
last: Optional[float] = None
for t in temps:
if t is None:
smoothed.append(None)
else:
last = t if last is None else alpha * t + (1.0 - alpha) * last
smoothed.append(last)
return smoothed
def compensate_weight(
weight_kg: Optional[float],
temp_c: Optional[float],
ref_temp_c: Optional[float],
coeff_kg_per_c: Optional[float],
) -> Optional[float]:
"""Apply the first-order temperature correction to a single weight.
Returns the raw weight unchanged whenever the correction cannot be applied
(missing weight, missing temperature, or a zero/None coefficient). This
makes the function safe to call unconditionally — a row without a usable
temperature simply passes through.
"""
if weight_kg is None:
return None
if not coeff_kg_per_c: # None or 0.0 → nothing to correct
return weight_kg
if temp_c is None:
return weight_kg
ref = DEFAULT_REF_TEMP_C if ref_temp_c is None else ref_temp_c
return weight_kg - coeff_kg_per_c * (temp_c - ref)
def apply_compensation(
rows: list,
temp_field: str,
ref_temp_c: Optional[float],
coeff_by_hive: dict,
alpha: float = DEFAULT_EMA_ALPHA,
) -> list:
"""Write compensated weights onto one device's serialized measurement dicts.
``rows`` are read-API measurement dicts for a *single* device (they share one
temperature series, so they are smoothed together). ``coeff_by_hive`` maps a
hive index to its kg/°C coefficient — hives 1–2 come from the
scale{1,2}_tempco_kg_per_c columns, hives 3..18 from the per-hive calibration
map — and only the hives listed there are compensated.
Each hive's raw weight is read from the flat ``scale_{n}_weight_kg`` key that
the read path synthesizes for every hive, and the result is written both to
``scale_{n}_weight_kg_compensated`` and onto the matching ``hives[]`` entry as
``weight_kg_compensated``, so flat and nested consumers agree.
Hives 1–2 always get their compensated key (defaulting to the raw weight, or
None, exactly as the uncompensated read path does); hives 3+ only get one when
that hive actually reported a weight, so an absent hive stays absent rather
than gaining a null field.
The rows are sorted by ``measured_at`` for the EMA and returned in that order;
the dicts are mutated in place.
"""
rows = sorted(rows, key=lambda m: m["measured_at"])
smoothed = ema_temperatures([m.get(temp_field) for m in rows], alpha)
for m, temp in zip(rows, smoothed):
by_index = {h.get("index"): h for h in (m.get("hives") or []) if h}
for n, coeff in coeff_by_hive.items():
raw_key = f"scale_{n}_weight_kg"
if n > 2 and m.get(raw_key) is None:
continue
value = compensate_weight(m.get(raw_key), temp, ref_temp_c, coeff)
m[f"{raw_key}_compensated"] = value
hive = by_index.get(n)
if hive is not None and hive.get("weight_kg") is not None:
hive["weight_kg_compensated"] = value
m["tempco_applied"] = True
return rows
def fit_temp_coefficient(samples: Iterable[tuple]) -> dict:
"""Least-squares fit of weight-vs-temperature drift.
``samples`` is an iterable of ``(temp_c, weight_kg)`` pairs, ideally captured
while the *physical* load is constant (an empty/unworked hive, or a fixed
reference mass) so that any weight variation is attributable to temperature.
Returns a dict describing the fit:
* ``coeff_kg_per_c`` — fitted slope, ready to store as the device coefficient.
* ``ref_temp_c`` — mean temperature of the window (the natural reference).
* ``intercept_kg`` — weight the model predicts at 0 °C (diagnostic only).
* ``r_squared`` — goodness of fit in ``[0, 1]``; low values mean the
drift is not well explained by temperature alone, so
the coefficient should be treated with suspicion.
* ``n`` — number of usable samples.
* ``temp_min_c`` / ``temp_max_c`` — span actually covered; a fit over a
narrow temperature range extrapolates poorly.
``ok`` is False (with a ``reason``) when there is not enough signal to fit
— fewer than two points, or zero temperature variation.
"""
pts = [
(float(t), float(w))
for t, w in samples
if t is not None and w is not None
]
n = len(pts)
base = {
"ok": False,
"coeff_kg_per_c": 0.0,
"ref_temp_c": DEFAULT_REF_TEMP_C,
"intercept_kg": None,
"r_squared": None,
"n": n,
"temp_min_c": None,
"temp_max_c": None,
}
if n < 2:
base["reason"] = "need at least 2 samples with both temperature and weight"
return base
temps = [t for t, _ in pts]
weights = [w for _, w in pts]
mean_t = sum(temps) / n
mean_w = sum(weights) / n
s_tt = sum((t - mean_t) ** 2 for t in temps)
s_tw = sum((t - mean_t) * (w - mean_w) for t, w in pts)
s_ww = sum((w - mean_w) ** 2 for w in weights)
base["temp_min_c"] = min(temps)
base["temp_max_c"] = max(temps)
if s_tt == 0.0:
base["reason"] = "temperature does not vary across the samples"
return base
slope = s_tw / s_tt
intercept = mean_w - slope * mean_t
r_squared = (s_tw * s_tw) / (s_tt * s_ww) if s_ww > 0 else 1.0
base.update(
ok=True,
coeff_kg_per_c=slope,
ref_temp_c=mean_t,
intercept_kg=intercept,
r_squared=r_squared,
)
return base
695b4ef90This file is pinned to the selected release. Download the original to open it in your design tool.