# Design
This design is adapted from the
[Mutable Instuments Tides schematics](https://mutable-instruments.net/modules/tides/downloads/tides_v40.pdf).
## Schematic
### Overview
This block allows to multiplex up to 8 3V3 value into a single value.
<p align="center"><img src="./schematic.png"></p>
Reading a particular input is done by setting the address on the `CBA` pins.
Below is the `ADDR` to `IN#` relation table. Note that `C` is the most significant bit.
| IN# | ADDR (CBA) |
| - | - |
| IN0 | 000 |
| IN1 | 001 |
| IN2 | 010 |
| IN3 | 011 |
| IN4 | 100 |
| IN5 | 101 |
| IN6 | 110 |
| IN7 | 111 |
## PCB Layout
<img src="./top.svg" height="275"> <img src="./bottom.svg" height="275">
> Gerber renders made with [tracespace view](https://tracespace.io/view/).
The bypass capacitor `C2` is placed 1mm from `U1`.
## Generating Production Files
The gerber files and the BOM in `csv` format can be produced by running the block `build.py`
script. It requires to be launched with the Python KiCad bundled executable.
The files are generated in the `artifacts` block directory.
When using macOS and KiCad is installed in the usual `/Applications` directory, the
`build.py` script can be runned directly from the shell, as the shebang line will automatically
select the right version of Python to run.
## Implementation
When `Module::run` is called, all `Multiplexer` configurations are retrieved to configure the
ADC converter, as the convertion time of the ADC is quite long and wouldn't fit real-time
constraints. The convertion result is stored in an address the `Multiplexer` class is lazily monitoring.
1c962d8cfThis file is pinned to the selected release. Download the original to open it in your design tool.