# Component Selection Rationale
---
## Mean Well HDR-60-12 Power Supply
Selected for its adjustable voltage range and efficiency characteristics:
- Adjustable voltage range (10.2–13.8V) enables precise 13.3V float setting
- 13.3V float operates 1.3V below BMS OVP trip point (14.4–14.6V) for safe margin
- 87% efficiency at 25% load vs 79% for LRS-100-12 at comparable loading
- MTBF 927,600 hrs — 37% higher than LRS-100-12
- Class II design (double-insulated) appropriate for ABS enclosure with no metal surfaces
- DIN rail mount capability, compact form factor
- OVP range of 13.8–16.2V provides a hard ceiling above the 13.3V float setpoint
At the 14.5W DC typical system load (~1.2A), the PSU operates at approximately 26% of its 4.5A rated capacity. Light loading reduces thermal stress and extends service life.
---
## Cyclenbatt 12V 10Ah LiFePO4 Battery
LiFePO4 chemistry selected over SLA for:
- Thermal stability: thermal runaway threshold above 270°C, non-flammable under normal conditions
- Cycle life: rated 5000+ cycles vs. 200–500 for SLA
- Calendar life: 10–20 years expected at 13.3V float and 63–75°F (1–2%/yr calendar aging) vs. 2–3 years for SLA at conventional float voltage
- Weight: approximately 40% lighter than equivalent SLA
Built-in 10A BMS provides cell-level over-voltage (14.4–14.6V), under-voltage (10.0V), and overcurrent protection as a secondary layer behind the system-level protections.
The 10Ah capacity provides approximately 7.8 hours runtime at the measured 14.5W DC combined load (Kill-a-Watt confirmed, 16.0W AC avg with adapter losses removed).
---
## Pololu Ideal Diode (4-60V, 10A) — Pololu #5382
A MOSFET-based ideal diode rather than a conventional Schottky diode eliminates the 0.6–0.7V forward voltage drop that would otherwise reduce the PSU-to-battery charging voltage. The MOSFET approach has approximately 5mΩ effective resistance at operating current — contributing only ~5mV drop at 1A vs. 600–700mV for a Schottky.
Function: blocks reverse current from battery to PSU during AC failure. Without this, the battery would attempt to back-power the PSU through its output terminals (PSU has no reverse protection).
10A rating provides 8× margin over 1.2A typical load (5× over 2A worst-case design current). Two units purchased; one installed, one spare.
---
## Victron BatteryProtect BP-65 (LVD)
See [design-rationale.md](design-rationale.md) for the relay module comparison.
Key specifications relevant to this installation:
- Setting 7: 11.8V disconnect / 12.8V reconnect — appropriate for LiFePO4 at this load level
- MOSFET Rds(on): ~3mΩ typical (community-validated; not published in datasheet)
- 90-second disconnect delay: prevents LVD trip on brief voltage sag from inrush or transient load; adds only ~0.02V additional drop during delay — negligible
- Over voltage protection: load disconnected if input exceeds 16.3V (12V system)
- Current consumption: 1.5mA with BLE on — negligible impact on battery runtime (0.018W parasitic)
- Bluetooth programming via VictronConnect app; thresholds are user-defined (not just preset table values)
- IP67 potted electronics, no calibration drift
- 5-year warranty
---
## DC-DC Converter — Design Decision (Not Purchased)
Originally specified: Mean Well DDR-60G-12 DC-DC converter. After analysis, this was dropped:
- HA Green and XB7 modem accept industry-standard ±10% on 12V rail
- Eliminated DDR-60G-12 saves $33.80 + 2.8W continuous loss (~$5/year electricity savings)
- Design is more reliable and efficient without it
---
## Shelly Plus Uni
Provides native Home Assistant integration via WiFi with no ESPHome coding required. Two analog inputs (ADC) and DS18B20 1-Wire temperature sensor support in a single module.
Pin 3 (Analog In) bridged to Pin 1 (V+) provides direct battery voltage sense — used as the primary low-battery warning trigger at 12.2V, giving Home Assistant time to initiate graceful HA Green shutdown before the Victron BP-65 LVD cutoff at 11.8V (approximately 15–20 minutes of runtime remaining).
The DS18B20 sensor is placed on the battery surface and provides temperature telemetry with a 40°C HA alert threshold.
Update rates: voltage every 5 seconds, temperature every 30 seconds. Power consumption: 0.5W in eco mode.
---
## LeMotech Junction Box
IP65-rated ABS enclosure with flame-retardant rating (UL94 fire safety standards). The 9.6″×7.6″×4.5″ interior provides adequate space for all components with room for cable management. Rubber gasket seal on lid. Pre-punched knockouts accept the 1/2" NPT cable glands.
ABS self-extinguishing rating is appropriate for an enclosure containing a lithium battery and 120VAC wiring — significantly safer than basic polypropylene storage containers. Six ¼″ ventilation holes have been drilled (3 intake low on PSU wall, 3 exhaust high on BP-65 wall). Thermal analysis confirms the holes contribute negligible active cooling (~0.05W, ~1.5% of total load) at the ~3.5W heat dissipation level — wall conduction dominates. The holes provide pressure equalization during thermal cycling. Note: the drilled holes reduce the enclosure rating from IP65 to approximately IP4X (splash-resistant; no longer water-jet resistant). This is a non-issue for an indoor floor installation.
Physical AC/DC segregation: PSU (AC input side) is mounted on the left; battery, BP-65, and DC components occupy the center and right. AC and DC cable glands are on opposite sides of the bottom face.