# Configuration Reference
## Configuration Domains
CubleyControl has two persisted configuration domains:
- **Network**: IPv4 assignment and DNS in the standard nanoFramework network
configuration block.
- **Application**: hostname and DiSEqC positioning calibration in the portable
512-byte schema-4 application record described in
[CONFIGURATION_STORAGE.md](CONFIGURATION_STORAGE.md).
Configuration is changed only through the USB CDC console. The REST API does
not expose configuration operations.
## Defaults
### Network
| Setting | Default |
|---|---|
| Address mode | DHCP |
| Static address, mask, gateway | `0.0.0.0` |
| DNS mode | Automatic |
| Static DNS servers | `0.0.0.0` |
### Application Schema 4
| Setting | Default | Valid values |
|---|---|---|
| Hostname | Automatic | Empty/`auto`, or a lowercase DNS label up to 63 characters using `a-z`, `0-9`, and internal hyphens |
| East angle limit | Disabled | `0`, or greater than 0 through 180 degrees |
| West angle limit | Disabled | `0`, or greater than 0 through 180 degrees |
| East step calibration | Disabled | `0`, or greater than 0 through 180 degrees per step |
| West step calibration | Disabled | `0`, or greater than 0 through 180 degrees per step |
| Signed GoToX offset | `0` | West 180 degrees through east 180 degrees |
East/west limits and east/west step calibration are each configured as a pair:
both values must be zero or both must be positive. Values are stored as integer
microdegrees. An automatic hostname resolves to `cubley-xxxxxx` from the STM32
unique device ID, or `cubley` if the ID is unavailable.
## USB CDC Configuration Mode
Enter configuration mode with `configure`, `config`, or `conf`; an optional
`terminal`/`t` token is accepted. Changes are staged in RAM until `commit`.
```text
cubley-a1b2c3> configure
cubley-a1b2c3(config)# hostname <name|auto>
cubley-a1b2c3(config)# network mode <dhcp|static>
cubley-a1b2c3(config)# network address <ipv4>
cubley-a1b2c3(config)# network mask <mask>
cubley-a1b2c3(config)# network gateway <ipv4>
cubley-a1b2c3(config)# network dns auto
cubley-a1b2c3(config)# network dns static <dns1> [dns2]
cubley-a1b2c3(config)# diseqc angle-limits <east> <west>|off
cubley-a1b2c3(config)# diseqc step-calibration <east> <west>|off
cubley-a1b2c3(config)# diseqc fixed-offset <east|west> <degrees>|off
cubley-a1b2c3(config)# show candidate-config [network|application|diseqc|all]
cubley-a1b2c3(config)# show running-config [network|application|diseqc|all]
cubley-a1b2c3(config)# show startup-config [network|application|diseqc|all]
cubley-a1b2c3(config)# show config diff
cubley-a1b2c3(config)# show storage
cubley-a1b2c3(config)# debug <on|off>
cubley-a1b2c3(config)# commit
cubley-a1b2c3(config)# discard
cubley-a1b2c3(config)# exit
```
`network defaults`, `diseqc defaults`, `load defaults [domain]`, and
`defaults [domain]` stage defaults. Supported domains are `network`,
`application`, `diseqc`, and `all`.
The prompt becomes `<hostname>(config*)#` while the candidate differs from the
running configuration. It continues to use the committed hostname until commit
succeeds. `exit`, `end`, and empty-line `Ctrl+D` refuse to leave configuration
mode while changes are pending. Use `commit` or `discard` explicitly.
`show running-config` omits default-valued lines. Startup and candidate views
render complete selected domains under a `! cubley-config v4 <source>` header.
`show storage` reports network and application backend/load status. `debug on`
shows successful setter details for the current USB session; failures are always
shown.
## Runtime Overrides
Operational `diseqc angle-limits <east> <west>` and `diseqc angle-limits off`
write the application record immediately and survive reboot. The runtime limits
change only after the write is verified. Operational `diseqc step-calibration`
commands remain RAM-only, and the fixed GoToX offset is changed only in
configuration mode.
The signed offset is applied before direction-specific limit checking and GoToX
encoding. For example, `diseqc fixed-offset west 3.38` changes a requested
36.6 degrees east to an effective 33.22 degrees east before protocol rounding.
The offset is an internal calibration factor. Reported positions stay in the
signed USALS domain, so the example above is reported as 36.58 degrees east
after protocol rounding, and the offset-adjusted motor angle is visible only in
USB `show diseqc detail`. The 0.02 degree difference between the entered and
reported angle is the 0.1 degree GoToX quantization; USB `show diseqc` reports it
as "Protocol rounding (estimate - request)".
## Commit And Recovery
`commit` validates the complete network and application candidates before
writing changed domains. The application write updates internal flash and
verifies readback. Network changes are applied through nanoFramework's network
configuration API.
If a write fails, the device attempts to restore both previous snapshots. A
successful rollback reports `persist_failed`; failed rollback reports
`persist_partial`. The candidate remains available for inspection. USB
disconnect or console timeout discards uncommitted changes.
The internal-flash application update is not power-fail atomic because the STM32
sector must be erased. CRC validation rejects incomplete or corrupt records and
the application starts with defaults.
## Related Documents
- [CONFIGURATION_STORAGE.md](CONFIGURATION_STORAGE.md)
- [INTERFACE_COMMAND_MAP_V1.md](INTERFACE_COMMAND_MAP_V1.md)
- [DEVICE_API_V2.md](DEVICE_API_V2.md)