# Sequential Logic Equivalence Checking (SLEC)
This folder contains a SLEC script that runs:
- LEC: Synopsys Formality and Cadence Design Systems Conformal.
- SEC: Siemens SLEC App
Please have a look at: https://cv32e40p.readthedocs.io/en/latest/core_versions/
The `cv32e40p_v1.0.0` tag refers to the frozen RTL. The RTL has been verified
and frozen on a given value of the input parameter of the design. Unless a bug
is found, it is forbidden to change the RTL in a non-logical equivalent manner
for PPA optimizations of any other change.
Instead, it is possible to change the RTL on a different value of the parameter
set, which has not been verified yet.
For example, it is possible to change the RTL design when the `FPU` parameter is
set to 1 as this configuration has not been verified yet. However, the design
must be logically equivalent when the parameter is set back to 0.
It is possible to change the `apu` interface and the `pulp_clock_en_i` signal on
the frozen parameter set as these signals are not used when the parameter `FPU`
and `PULP_CLUSTER` are set to 0, respectively.
The current scripts have been tried on Synopsys Formality `2021.06-SP5` ,
Cadence Design Systems Conformal `20.20` and Siemens SLEC App `2023.4`.
### Running the script
From a bash shell using LEC, please execute:
```
./run.sh -t synopsys -p lec
```
or
```
./run.sh -t cadence -p lec
```
From a bash shell to use SEC, please execute:
```
./run.sh -t siemens -p sec
```
By default `cv32e40p_core` is used as a top module, if you want to use
another one set the `TOP_MODULE` environment variable.
The script clones the `cv32e40p_v1.0.0` tag of the core as a golden reference,
and uses the current repository's `rtl` as revised version.
If you want to use another golden reference RTL, set the `GOLDEN_RTL`
environmental variable to the new RTL before calling the `run.sh` script.
```
export GOLDEN_RTL=YOUR_GOLDEN_CORE_RTL_PATH
```
or
```
setenv GOLDEN_RTL YOUR_GOLDEN_CORE_RTL_PATH
```
### Additional improvements for v2
To be able to make LEC checks between v2 versions, the scripts have been augmented with additional optional switches:
* for RTL version : -v v1 or v2
* for PULP instructions selection : -x 0 or 1
* for FPU instructions selection : -f 0 or 1
* for ZFINX selection : -z 0 or 1
When those options are not used, present behavior is happenning, meaning verifying local RTL files with `cv32e40p_v1.0.0` tag.
When v2 option is selected, `cv32e40p_top` is used as a top module, including both `cv32e40p_core` and `CVFPU`.
CAUTION : Right now dev branch is cloned as a golden reference when v2 version is used. It will have to be changed to `cv32e40p_v2.0.0` tag after CV32E40Pv2 RTL freeze.
From a bash shell using LEC, please execute:
```
./run.sh -t synopsys -p lec -v v2 -x 1 -f 1
```
6033d2b1bThis file is pinned to the selected release. Download the original to open it in your design tool.