Loading files
This file is pinned to the selected release. Download the original to open it in your design tool.
# SPDX-FileCopyrightText: Copyright (c) 2026 TiaC Systems
# SPDX-License-Identifier: Apache-2.0
menu "RGB matrix level sample settings"
config LEVEL_COLOR_RANGE_TILT
int "Tilt angle over which the bubble changes colour [tenths of a degree]"
range 1 600
default 10
help
At this angle and beyond, the bubble is fully the far colour; at
dead level it is fully the near colour; in between it is mixed.
Should be far tighter than LEVEL_FULL_SCALE_TILT.
config LEVEL_LOCK_TILT
int "Tilt angle below which the board counts as level [tenths of a degree]"
range 0 600
default 3
help
Below this tilt the bubble latches fully to the near colour.
Keep well inside LEVEL_COLOR_RANGE_TILT. Set to 0 to disable
the latch.
config LEVEL_LOCK_HYSTERESIS
int "Extra tilt needed to break the level latch [tenths of a degree]"
range 0 600
default 2
help
The latch engages at LEVEL_LOCK_TILT and releases at
LEVEL_LOCK_TILT plus this, so the two form a band rather than
a single edge that would flicker on noise.
config LEVEL_FULL_SCALE_TILT
int "Tilt angle at which the bubble reaches the panel edge [degrees]"
range 1 60
default 10
help
Tilt that moves the bubble from the centre of the panel all the
way to the rim; sets the sensitivity of the instrument.
config LEVEL_FILTER_TIME_CONSTANT
int "Low pass filter time constant [milliseconds]"
range 0 5000
default 100
help
Time constant of the first order low pass filter on the
acceleration reading. Set to 0 to disable filtering. Quoted as
a time rather than a per sample weight, so the smoothing is
independent of LEVEL_FRAME_INTERVAL.
config LEVEL_FRAME_INTERVAL
int "Delay between two frames [milliseconds]"
range 1 10000
default 40
help
Also the rate at which the inertial sensor is polled.
config LEVEL_SENSOR_LOG_INTERVAL
int "Delay between two logged sensor readings [milliseconds]"
range 0 60000
default 1000
help
Throttles the log output only; sampling always runs at
LEVEL_FRAME_INTERVAL. Set to 0 to log every sample.
config LEVEL_TEST_IMAGE_MS
int "Show the corner test image at startup [milliseconds]"
range 0 10000
default 2000
help
Lights the four corner pixels in red, green, blue and white to
show where the origin of the display physically sits. Set to 0
to skip the test image.
menu "Sensor to panel axis mapping"
comment "Determine these empirically, see the README"
# How the sensor is mounted relative to the panel is a per board
# property, so measured boards get their mapping as a default here and
# every other board falls back to the identity mapping.
config LEVEL_AXIS_SWAP_XY
bool "Swap the sensor X and Y axes"
default y if BOARD_WAVESHARE_RP2350_MATRIX
help
Feed the sensor Y axis into the panel X axis and vice versa.
Applied before the inversions.
config LEVEL_AXIS_INVERT_X
bool "Invert the panel X axis"
default y if BOARD_WAVESHARE_RP2350_MATRIX
help
Negate the horizontal component, after any swap.
config LEVEL_AXIS_INVERT_Y
bool "Invert the panel Y axis"
help
Negate the vertical component, after any swap.
endmenu
config LEVEL_BRIGHTNESS
int "Brightness of the bubble and the test image"
range 1 255
default 32
help
The channel level a fully lit primary colour is drawn at. This
is also the number of brightness steps the sub-pixel
positioning has to work with.
module = LEVEL
module-str = "level"
source "subsys/logging/Kconfig.template.log_config"
endmenu
# Sources Kconfig.zephyr in the Zephyr root directory.
menu "Zephyr Kernel"
source "Kconfig.zephyr"
endmenu
efd4b04f2This file is pinned to the selected release. Download the original to open it in your design tool.