"""Tests for the ``akcli plan`` / ``akcli draw`` CLI (SPEC §3.5 / §3.7).
Drives the real CLI ``main()`` over a copy of the synthetic ``board_v8.kicad_sch``
fixture with a small op-list:
* ``plan`` validates + dry-runs (per-op preview + connectivity) and NEVER writes;
* ``draw`` without ``--apply`` is dry-run (no write);
* ``draw --apply`` writes atomically and the result re-parses;
* exit codes honour ``errors.EXIT`` — ``OPLIST=6`` on an op/verify failure,
``USAGE=2`` for a missing ``--ops``, ``0`` on success.
"""
from __future__ import annotations
import json
from pathlib import Path
from akcli import ops as ops_mod
from akcli.cli import main
from akcli.errors import EXIT
from akcli.sexpr import parser as sexpr
FIX = Path(__file__).parent / "fixtures" / "kicad"
V8 = FIX / "board_v8.kicad_sch"
# --------------------------------------------------------------------------- #
# helpers
# --------------------------------------------------------------------------- #
def _copy(tmp_path: Path) -> Path:
tgt = tmp_path / "board.kicad_sch"
tgt.write_bytes(V8.read_bytes())
return tgt
def _ops_file(tmp_path: Path, ops: list, *, protocol=ops_mod.PROTOCOL_VERSION,
target="kicad", name="ops.json") -> Path:
p = tmp_path / name
p.write_text(json.dumps(
{"protocol_version": protocol, "target_format": target, "ops": ops}
))
return p
_GOOD_OPS = [
{"op": "place_component", "lib_id": "Device:R", "designator": "R9",
"x_mil": 7000, "y_mil": 4000, "value": "1k"},
{"op": "add_wire", "vertices": ["R9.1", "R9.2"]},
]
# --------------------------------------------------------------------------- #
# plan
# --------------------------------------------------------------------------- #
def test_plan_exit_zero_and_no_write(tmp_path, capsys):
tgt = _copy(tmp_path)
ops = _ops_file(tmp_path, _GOOD_OPS)
before = tgt.read_bytes()
rc = main(["plan", str(tgt), "--ops", str(ops)])
out = capsys.readouterr().out
assert rc == EXIT["OK"]
assert tgt.read_bytes() == before # plan never writes
assert "place_component" in out # per-op preview
assert "connectivity" in out
def test_plan_json(tmp_path, capsys):
tgt = _copy(tmp_path)
ops = _ops_file(tmp_path, _GOOD_OPS)
rc = main(["plan", str(tgt), "--ops", str(ops), "--json"])
payload = json.loads(capsys.readouterr().out)
assert rc == EXIT["OK"]
assert payload["applied"] is False
assert [o["status"] for o in payload["ops"]] == ["ok", "ok"]
# --------------------------------------------------------------------------- #
# draw
# --------------------------------------------------------------------------- #
def test_draw_dry_run_no_write(tmp_path):
tgt = _copy(tmp_path)
ops = _ops_file(tmp_path, _GOOD_OPS)
before = tgt.read_bytes()
rc = main(["draw", str(tgt), "--ops", str(ops)])
assert rc == EXIT["OK"]
assert tgt.read_bytes() == before # dry-run is the default
def test_draw_apply_writes(tmp_path):
tgt = _copy(tmp_path)
ops = _ops_file(tmp_path, _GOOD_OPS)
before = tgt.read_bytes()
rc = main(["draw", str(tgt), "--ops", str(ops), "--apply"])
assert rc == EXIT["OK"]
assert tgt.read_bytes() != before
doc = sexpr.parse(tgt.read_text()) # re-parses cleanly
refs = []
for s in doc.find_all("symbol"):
inst = s.find("instances")
if inst:
for proj in inst.find_all("project"):
for path in proj.find_all("path"):
r = path.find("reference")
if r:
refs.append(r.children[1].value)
assert "R9" in refs
def test_draw_apply_idempotent(tmp_path):
tgt = _copy(tmp_path)
ops = _ops_file(tmp_path, _GOOD_OPS)
main(["draw", str(tgt), "--ops", str(ops), "--apply"])
once = tgt.read_bytes()
main(["draw", str(tgt), "--ops", str(ops), "--apply"])
assert tgt.read_bytes() == once
def test_draw_apply_idempotent_with_power_port(tmp_path):
"""A power port (auto-allocated ``#PWR0<n>`` ref) must re-apply byte-identically.
Regression: ``alloc_pwr_ref`` is doc-state-dependent, so a naive second apply
re-numbered the port (#PWR0n -> #PWR0n+1), changing its deterministic uuid and
appending a duplicate. The op must reuse the ref it allocated on the first run.
"""
tgt = _copy(tmp_path)
ops = _ops_file(tmp_path, [
{"op": "place_component", "lib_id": "Device:R", "designator": "R9",
"x_mil": 7000, "y_mil": 4000, "value": "1k"},
{"op": "place_component", "lib_id": "Device:C", "designator": "C9",
"x_mil": 7000, "y_mil": 5000, "value": "100n"},
{"op": "place_power_port", "lib_id": "power:GND", "net_name": "GND",
"at": [7000, 6000]},
{"op": "add_wire", "vertices": ["R9.2", "C9.1"]},
])
main(["draw", str(tgt), "--ops", str(ops), "--apply"])
once = tgt.read_bytes()
main(["draw", str(tgt), "--ops", str(ops), "--apply"])
assert tgt.read_bytes() == once
# re-parses cleanly and the power port was placed exactly once
doc = sexpr.parse(tgt.read_text())
refs = [r for r in _all_refs(doc) if r.startswith("#PWR")]
assert refs.count("#PWR03") == 1
def _all_refs(doc) -> list[str]:
out: list[str] = []
for sym in doc.find_all("symbol"):
if sym.find("lib_id") is None:
continue
for prop in sym.find_all("property"):
kids = prop.children or []
if len(kids) >= 3 and kids[1].value == "Reference" and kids[2].value:
out.append(kids[2].value)
return out
def test_draw_apply_json(tmp_path, capsys):
tgt = _copy(tmp_path)
ops = _ops_file(tmp_path, _GOOD_OPS)
rc = main(["draw", str(tgt), "--ops", str(ops), "--apply", "--json"])
payload = json.loads(capsys.readouterr().out)
assert rc == EXIT["OK"]
assert payload["applied"] is True
# --------------------------------------------------------------------------- #
# failure exit codes
# --------------------------------------------------------------------------- #
def test_draw_bad_symbol_exit_oplist(tmp_path):
tgt = _copy(tmp_path)
before = tgt.read_bytes()
ops = _ops_file(tmp_path, [
{"op": "place_component", "lib_id": "Device:NOPE", "designator": "Z1",
"x_mil": 1000, "y_mil": 1000},
])
rc = main(["draw", str(tgt), "--ops", str(ops), "--apply"])
assert rc == EXIT["OPLIST"]
assert tgt.read_bytes() == before
def test_plan_structurally_invalid_oplist_exit_oplist(tmp_path):
tgt = _copy(tmp_path)
# an unsupported protocol_version fails structural validation -> exit 6,
# no traceback
ops = _ops_file(tmp_path, _GOOD_OPS, protocol=ops_mod.PROTOCOL_VERSION + 1)
rc = main(["plan", str(tgt), "--ops", str(ops)])
assert rc == EXIT["OPLIST"]
def test_draw_missing_ops_is_usage_error(tmp_path):
tgt = _copy(tmp_path)
rc = main(["draw", str(tgt)])
assert rc == EXIT["USAGE"]
def test_draw_missing_target_is_usage_error(tmp_path):
ops = _ops_file(tmp_path, _GOOD_OPS)
rc = main(["draw", "--ops", str(ops)])
assert rc == EXIT["USAGE"]
def test_draw_apply_plus_dry_run_never_writes(tmp_path, capsys):
# a defensively added --dry-run must win over --apply (safety flag first)
tgt = _copy(tmp_path)
ops = _ops_file(tmp_path, _GOOD_OPS)
before = tgt.read_bytes()
rc = main(["draw", str(tgt), "--ops", str(ops), "--apply", "--dry-run"])
err = capsys.readouterr().err
assert rc == EXIT["OK"]
assert tgt.read_bytes() == before
assert "honoring --dry-run" in err
def test_unknown_pin_error_lists_valid_pins(tmp_path, capsys):
tgt = _copy(tmp_path)
ops = _ops_file(tmp_path, [
{"op": "place_component", "lib_id": "Device:R", "designator": "R9",
"x_mil": 7000, "y_mil": 4000},
{"op": "add_wire", "vertices": ["R9.3", [7000, 4300]]},
])
rc = main(["plan", str(tgt), "--ops", str(ops)])
out = capsys.readouterr().out
assert rc == EXIT["OPLIST"]
assert "valid pins: 1, 2" in out
# --------------------------------------------------------------------------- #
# op-list EDITING must not duplicate untouched parts (designator-seeded uuids)
# --------------------------------------------------------------------------- #
def test_insert_op_then_reapply_does_not_duplicate(tmp_path, capsys):
tgt = _copy(tmp_path)
base = [
{"op": "place_component", "lib_id": "Device:R", "designator": "R21",
"x_mil": 7000, "y_mil": 4000, "value": "1k"},
{"op": "place_component", "lib_id": "Device:R", "designator": "R22",
"x_mil": 7000, "y_mil": 4600, "value": "2k"},
]
ops1 = _ops_file(tmp_path, base, name="ops1.json")
assert main(["draw", str(tgt), "--ops", str(ops1), "--apply"]) == EXIT["OK"]
capsys.readouterr()
# Insert a NEW op at the FRONT — downstream ops all shift index.
edited = [
{"op": "place_component", "lib_id": "Device:R", "designator": "R20",
"x_mil": 7000, "y_mil": 3400, "value": "3k"},
*base,
]
ops2 = _ops_file(tmp_path, edited, name="ops2.json")
assert main(["draw", str(tgt), "--ops", str(ops2), "--apply"]) == EXIT["OK"]
capsys.readouterr()
text = tgt.read_text(encoding="utf-8")
for ref in ("R20", "R21", "R22"):
assert text.count(f'(reference "{ref}"') == 1, ref
def test_duplicate_designator_gate_flags_literal_dup(tmp_path, capsys):
"""A doc carrying the same ref+unit on two symbol nodes must not verify."""
import re
from akcli.sexpr import parser as sx
from akcli.writers import connectivity
tgt = _copy(tmp_path)
ops = _ops_file(tmp_path, [
{"op": "place_component", "lib_id": "Device:R", "designator": "R31",
"x_mil": 7000, "y_mil": 4000, "value": "1k"},
])
assert main(["draw", str(tgt), "--ops", str(ops), "--apply"]) == EXIT["OK"]
capsys.readouterr()
text = tgt.read_text(encoding="utf-8")
assert not [f for f in connectivity.verify(sx.parse(text))
if f.code == "DUPLICATE_DESIGNATOR"]
# Clone R31's placed-symbol block (balanced-paren scan) under fresh uuids.
start = text.rindex("(symbol (lib_id", 0, text.index('"R31"'))
depth, i = 0, start
in_str = False
while True:
c = text[i]
if c == '"' and text[i - 1] != "\\":
in_str = not in_str
elif not in_str and c == "(":
depth += 1
elif not in_str and c == ")":
depth -= 1
if depth == 0:
break
i += 1
block = text[start:i + 1]
clone = re.sub(r'"([0-9a-f]{8})(-[0-9a-f-]{27})"',
lambda g: '"deadbeef' + g.group(2) + '"', block)
assert clone != block
dup = text[:text.rindex(")")] + "\n" + clone + "\n)"
findings = connectivity.verify(sx.parse(dup))
assert [f for f in findings if f.code == "DUPLICATE_DESIGNATOR"]
# --------------------------------------------------------------------------- #
# keyless nodes are op-index-free too (audit): editing an op-list must not
# duplicate the wires / labels / annotations downstream of the edit
# --------------------------------------------------------------------------- #
_KEYLESS_OPS = [
{"op": "place_component", "lib_id": "Device:R", "designator": "R41",
"x_mil": 7000, "y_mil": 4000, "value": "1k"},
{"op": "add_text", "text": "reviewed", "at": [7500, 3000]},
{"op": "add_wire", "vertices": ["R41.1", "R41.2"]},
{"op": "add_net_label", "name": "SENSE", "at": "R41.1"},
]
def _count_tags(tgt: Path) -> dict[str, int]:
doc = sexpr.parse(tgt.read_text(encoding="utf-8"))
out: dict[str, int] = {}
for c in doc.children or []:
if c.is_list and (c.children or []):
tag = c.children[0].value or ""
out[tag] = out.get(tag, 0) + 1
return out
def test_keyless_nodes_survive_an_op_list_edit(tmp_path, capsys):
"""Insert an op at the FRONT, re-apply: text/wire/label must not double.
Regression (0.17 fixed only symbols/pins): wire, junction, no_connect,
label, bus_entry, annotation and sheet uuids were still seeded with the op
INDEX, so one inserted op re-identified every node after it and the next
apply stacked a second copy of each (two `add_text` notes on one point).
"""
tgt = _copy(tmp_path)
ops1 = _ops_file(tmp_path, _KEYLESS_OPS, name="ops1.json")
assert main(["draw", str(tgt), "--ops", str(ops1), "--apply"]) == EXIT["OK"]
capsys.readouterr()
before = _count_tags(tgt)
edited = [{"op": "place_component", "lib_id": "Device:R",
"designator": "R40", "x_mil": 7000, "y_mil": 3400,
"value": "3k"}, *_KEYLESS_OPS]
ops2 = _ops_file(tmp_path, edited, name="ops2.json")
assert main(["draw", str(tgt), "--ops", str(ops2), "--apply"]) == EXIT["OK"]
capsys.readouterr()
after = _count_tags(tgt)
for tag in ("text", "wire", "label"):
assert after[tag] == before[tag], (tag, before, after)
assert tgt.read_text(encoding="utf-8").count('"reviewed"') == 1
def test_keyless_ops_replay_byte_identically(tmp_path, capsys):
tgt = _copy(tmp_path)
ops = _ops_file(tmp_path, _KEYLESS_OPS)
assert main(["draw", str(tgt), "--ops", str(ops), "--apply"]) == EXIT["OK"]
once = tgt.read_bytes()
assert main(["draw", str(tgt), "--ops", str(ops), "--apply"]) == EXIT["OK"]
capsys.readouterr()
assert tgt.read_bytes() == once
def test_two_identical_keyless_ops_collide_loudly(tmp_path, capsys):
"""Content-seeded uuids mean a literal duplicate op would OVERWRITE the
first node while both report ok — refuse instead, naming both ops."""
tgt = _copy(tmp_path)
before = tgt.read_bytes()
ops = _ops_file(tmp_path, [
{"op": "add_text", "text": "A", "at": [7500, 3000]},
{"op": "add_text", "text": "B", "at": [7500, 3000]},
])
rc = main(["draw", str(tgt), "--ops", str(ops), "--apply"])
out = capsys.readouterr().out
assert rc == EXIT["OPLIST"]
assert "collides with op [0]" in out
assert tgt.read_bytes() == before
# --------------------------------------------------------------------------- #
# power-port identity is the COORDINATE (audit P0)
# --------------------------------------------------------------------------- #
def _power_values_at(tgt: Path, x_mil: float, y_mil: float) -> list[str]:
"""``Value`` of every ``#``-referenced symbol anchored exactly at x/y mil."""
want = (round(x_mil * 0.0254, 4), round(y_mil * 0.0254, 4))
doc = sexpr.parse(tgt.read_text(encoding="utf-8"))
out = []
for sym in doc.find_all("symbol"):
at = sym.find("at")
if sym.find("lib_id") is None or at is None:
continue
pos = (round(float(at.children[1].value), 4),
round(float(at.children[2].value), 4))
props = {}
for prop in sym.find_all("property"):
kids = prop.children or []
if len(kids) >= 3:
props[kids[1].value] = kids[2].value
if pos == want and props.get("Reference", "").startswith("#"):
out.append(props.get("Value", ""))
return sorted(out)
def test_power_port_net_rename_replaces_in_place(tmp_path, capsys):
"""GND -> +3V3 at the same coordinate must REPLACE the port, not stack one.
0.17 keyed a port's identity on position AND net name, so the renamed op
matched nothing, allocated a fresh #PWR ref and appended a second symbol on
top of the first: the stale GND stayed, invisible, shorting GND into +3V3.
"""
tgt = _copy(tmp_path)
gnd = _ops_file(tmp_path, [
{"op": "place_power_port", "lib_id": "power:GND", "net_name": "GND",
"at": [7000, 6000]},
], name="gnd.json")
assert main(["draw", str(tgt), "--ops", str(gnd), "--apply"]) == EXIT["OK"]
capsys.readouterr()
assert _power_values_at(tgt, 7000, 6000) == ["GND"]
v33 = _ops_file(tmp_path, [
{"op": "place_power_port", "lib_id": "power:+3V3", "net_name": "+3V3",
"at": [7000, 6000]},
], name="v33.json")
assert main(["draw", str(tgt), "--ops", str(v33), "--apply"]) == EXIT["OK"]
capsys.readouterr()
# exactly one power symbol there, now naming +3V3 — no orphaned GND under it
assert _power_values_at(tgt, 7000, 6000) == ["+3V3"]
def test_two_power_ports_on_one_point_are_refused(tmp_path, capsys):
tgt = _copy(tmp_path)
before = tgt.read_bytes()
ops = _ops_file(tmp_path, [
{"op": "place_power_port", "lib_id": "power:GND", "net_name": "GND",
"at": [7000, 6000]},
{"op": "place_power_port", "lib_id": "power:+3V3", "net_name": "+3V3",
"at": [7000, 6000]},
])
rc = main(["draw", str(tgt), "--ops", str(ops), "--apply"])
cap = capsys.readouterr()
assert rc == EXIT["OPLIST"]
# the op-list validator catches this before the writer ever runs; the
# writer keeps its own guard for library callers that skip validation, and
# both report the same code
assert "POWER_PORT_STACKED" in cap.out + cap.err
assert tgt.read_bytes() == before
def test_two_identical_power_ports_are_refused(tmp_path, capsys):
"""Same coordinate AND same net: 0.17 wrote one over the other, both ok."""
tgt = _copy(tmp_path)
ops = _ops_file(tmp_path, [
{"op": "place_gnd", "at": [7000, 6000]},
{"op": "place_gnd", "at": [7000, 6000]},
])
rc = main(["draw", str(tgt), "--ops", str(ops), "--apply"])
cap = capsys.readouterr()
assert rc == EXIT["OPLIST"]
assert "POWER_PORT_STACKED" in cap.out + cap.err